1260-43 User Manual
Racal Instruments
©
2006
Specifications 1-3
Specifications
Bandwidth (-3dB)
40 MHz
Isolation
100 KHz
> 80 dB
1 MHz
> 70 dB
10 MHz
> 45 dB
Insertion Loss
10 MHz
< 1 dB
40 MHz
< 3 dB
Crosstalk
100 KHz
< -70 dB
1 MHz
< -60 dB
10 MHz
< -50 dB
Switching Voltage
AC
250 V, Max
DC
220 V, Max
Switching Current
AC
2 A, Max.
DC
2 A, Max
Switching Power
60W, 62.5 VA, Max
Path resistance
< 900 m
Ω
@ 2A
Capacitance
Shunt
< 0.5 uF
Crosstalk
< 0.36 uF
Insulation resistance
> 10
9
Ω
Relay Settling Time
< 10 ms
Shock
30g, 11 ms, ½ sine wave
Vibration
0.013 in. P-P, 5-55 Hz
Bench Handling
4 in., 45
°
Cooling
Airflow: 5.6 liters/sec
Backpressure: 0.59 mm H2O
Temperature
Operating
0
°
C to +55
°
C
Non-operating -40
°
C to +75
°
C
Relative Humidity
85%, non-condensing at < 30
°
C
Summary of Contents for 1260-43