User’s Manual
79
D.4 D/A Converter
The output will initially be 0 V to -10.05 V after the first inverting op-amp, and 0 V to
+10.05 V after the second inverting op-amp. All lows produce 0 V out, FF produces 10 V
out. The output can be scaled by changing the feedback resistors on the op-amps. For
example, changing 5.11 k
Ω
to 2.5 k
Ω
will produce an output from 0 V to -5 V. Op-amps
with a very low input offset voltage are recommended.
Figure D-5. Sample D/A Converter Connections
+
+
649 k
W
324 k
W
162 k
W
80.6 k
W
40.2 k
W
20 k
W
10 k
W
5.11 k
W
CT0CT7
PA0PA7
HC374
47 k
W
47 k
W
CLK
E
+5 V
+5 V
PE2
PE4
1.19 k
W
4.99 k
W
10 k
W
10 k
W
5.11 k
W
22 pF
22 pF
V
o
V+ > 12 V