INSTRUCTIONS
SWISH® FA INSTALLATION
RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi cient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
Fig: 1
Fig: 2
Fig: 3
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside.
CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened
fi rmly. Apply weatherproof silicone sealant around the edge of the ceiling mounting box and/or junction box. This is
especially important with an uneven ceiling surface. Silicone all plugs and unused conduit entries.
RECESSED CEILING MOUNTING
The fi xture is suitable only for INDOOR RECESSED CEILING
application. Above ceiling access required.
To mount in an insulated or non-insulated ceiling -
9/16” or 15/16”
exposed Flat Tee Grid Ceiling follow the steps below.
1.
Rotate and slide the
Housing
as required to fi t through the
Tee-Grid Bar
and place it as indicated by the directional arrow
as shown in Fig. 1.
2. Firmly bend the pre-installed
Grid Clips
(4)
against the
Tee-Grid Bar
to secure the
Housing
as shown in Fig. 2
3. Support wires are required by Installation Codes. Support the
Housing
to the building structure by
Support Wires
(supplied by
others)
through the
Support Wire Hole
as shown in Fig. 3.
4.
Make sure that the orientation of the
Access Plate
faces an
accessible tile to make electrical splices.
5. Loosen screw on
Access Plate
and remove the
Access Plate
(Fig. 1)
. Knock out appropriate
Conduit Knockouts
on the
Access Plate
to route input conduit. Use appropriate conduit
connectors as required by code.
6. Connect wires as shown in wiring diagram
(Fig 4).
Push all
wires back into the
Splice Box.
Be careful not to pinch wires.
WARNING: To prevent wiring damage or abrasion, do not
expose wiring to edges of sheet metal or other
sharp objects.
7.
Replace
Access Plate
and tighten
Access Plate Screw.
8. After installation remove protective fi lm from the outer surface
of the lens.
SWISHFA -2X2
SWISHFA -2X4
Tee-Grid
Bar
Access Plate
Screw
Housing
Grid Clip
Support Wire
(supplied by others)
Conduit Knockouts
Firmly bend Grid
Clips against the
Tee-Grid Bar
Tee-Grid Bar
Housing
nominal 4”
Support Wire Hole
Support Wire
(supplied by others)
Tee-Grid Bar
Access Plate
Grid Clips
(4)