background image

INSTRUCTIONS

 

STL110H/L, STL110HB/L, STL110R/L INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

WIRING

Fig. 5

Fig. 6

WIRING

Bar 

Hook 

Screws

CU4 EZ

Plate

Universal

Mounting Bar

Gasket

Center 

Screw

Insert

close-up

plugs in

unused

holes

Finishing

Cap

O-Ring Gasket

Black

Black

Red

   Red

(pigtail)

Ground

Ground

Power In

White

White

Note:  

These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Red pigtail is only used to switch remote or additional fixtures.

1. Attach the 

Universal Mounting Bar

 with the 

Bar Screws

(provided) to the junction box as shown in 

Fig 5

. If you are

attaching your STL110 kit to a surface mount weatherproof box,
you must use the metal plate with the attached gasket.
The gasket faces the Junction Box.

2. Easy Wiring Tip: Use the “S” shaped 

Hands Free Hanging Hook

to hold the 

EZ Plate

 during wiring.

3. Bring power leads and sensor kit leads through holes in all

gaskets into junction box.

4. Strip 1/2” of insulation from all leads.
5. Attach ground wire(s) to junction box grounding screw.

Connect as shown in 

Fig 6

.

6. Twist on wire nuts. Secure with electrical  tape.
7. Align 

EZ Plate

 and metal mounting plate to insure proper seal.

Tighten 

EZ Plate

 center screw (make sure 

O-Ring Gasket

 is

on the screw) to attach 

EZ Plate

 to the box. There are 2 screws

supplied. Use the one which suits your assembly best.

8. Insert plastic 

Finishing Cap

 in the center of the 

EZ Plate

 for a

weatherproof seal.

9. Use silicone sealant around all openings to insure a

weatherproof seal.

10. Screw in lamps (if not already installed). Turn on power.

Conduct walk test to adjust sensor response.

Fig. 7

SWITCHPLATE LABEL

STL110

Switchplate label with self-adhesive backing 

(Fig 7)

.

Attach Stealth operating instruction label to switchplate for quick 
and easy reference. 

Summary of Contents for STL110H/L

Page 1: ...R GARAGE DOOR OPENERS Sensor must be below and as far as possible away from lights Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor...

Page 2: ...the lens For night only operation turn the knob all the way clockwise to to the moon symbol For 24 hour operation turn the knob all the way counterclockwise sun moon Adjust clockwise to have the senso...

Page 3: ...g your STL110 kit to a surface mount weatherproof box you must use the metal plate with the attached gasket The gasket faces the Junction Box 2 Easy Wiring Tip Use the S shaped Hands Free Hanging Hook...

Page 4: ...area Lights Do Not Turn Off 1 Make sure that the sensor is not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 5 minutes then it will switch...

Page 5: ...dedicated circuit free of motor loads such as HVAC equipment kitchen appliances or garage door openers 2 It is not recommended to wire sensors in parallel More than one sensor wired together makes the...

Page 6: ...in higher ambient light levels turn the photocell control center knob toward the sun symbol 4 Was sensor wired hot If so circuitry may have been damaged Range Appears Limited 1 Check that the sensor...

Page 7: ...etection Much Sooner PATHWAY 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move the sensor 4 Check that movement far away and dir...