IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

  

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is 
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS:  
• Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.
  CAUTION:  
• This fixture supports the following protocols – Triac and ELV at 120V ONLY. For 0-10V dimming, connect purple wire to the

V+ DIM lead and the grey wire to the V-DIM lead. This fixture is damp listed and suitable for indoor applications on walls. 
Driver is 120V – 277V and 50Hz or 60 Hz

.

HALV

Mounting the fixture on a standard 4 x 4 J-BOX

This fixture is damp listed and suitable for indoor applications 
on walls

1.  Loosen the (4) 

driver/LED mounting

 phillips head screws and 

separate the 

driver/LED assembly

 from the wall plate. No need 

to remove the screws completely, use the keyhole. 

DO NOT 

TOUCH THE LEDs

. See 

Figure 1

.

2.  Set 

Driver/LED

 assembly aside.

3.  Pull wires from j-box through the 

Wall Plate

 opening and 

mount Wall Plate to junction box using screws provided with the 
junction box. Making sure the 

‘S’ hook

 notch is at the top.

4.  Hang the 

Driver/LED Assembly

 on the 

‘S’ hook

 as shown in 

Figure 1a

.

5.  Make wiring connections. Push wire nuts through hole into 

 

J box.

6.  Replace 

Driver/LED Assembly

 making sure not to pinch any 

wires.

7.  Tighten Driver/LED mounting screws.

J-BOX WALL MOUNTING

 (standard models)

‘S’ Hook Notch

Wall Plate

Driver/LED

Assembly

DO NOT TOUCH LEDs

Driver/LED

Screw Keyhole

Wire Hole

Driver/LED mounting screws

‘S’ Hook

FIG.1

‘S’ Hook

‘S’ Hook

FIG.1a

Summary of Contents for HALV

Page 1: ...s the following protocols Triac and ELV at 120V ONLY For 0 10V dimming connect purple wire to the V DIM lead and the grey wire to the V DIM lead This fixture is damp listed and suitable for indoor applications on walls Driver is 120V 277V and 50Hz or 60 Hz HALV Mounting the fixture on a standard 4 x 4 J BOX This fixture is damp listed and suitable for indoor applications on walls 1 Loosen the 4 dr...

Page 2: ... to box Wall box is installed after sheetrock 1 Remove Driver LED Wall plate assembly by loosening 4 phillips head screws as shown in Figure 1 No need to completely remove screws keyhole slots provided Retain Hanger Unplug connectors if E2 E2 MVS E2 E2 BL or LC E2 and put Driver LED Wall plate aside 2 Discard Nailer Bars 3 Move Stop Brackets from end to side and add Sheetrock Clamps as shown in Fi...

Page 3: ...e over the Driver LED assembly with the phillips head mounting screw at the top See Figure 5 2 Inset the lens frame from the bottom with the bottom flush against the wall See Figure 5 3 Tilt the top of the lens frame to the wall 4 Make sure the frame is flush against the wall and tighten mounting screw at the top using a 5 64 hex key LENS FRAME INSTALLATION Driver LED Assembly DO NOT TOUCH LEDs Mo...

Page 4: ...t at 888 RAB 1000 or email marketing rablighting com Easy Answers rablighting com Visit our website for product info Tech Help Line Call our experts 888 722 1000 e mail Answered promptly sales rablighting com Free Lighting Layouts Answered online or by request 2019 RAB LIGHTING Inc Northvale New Jersey 07647 USA DIMENSIONAL DRAWINGS LENS FRAME ASSEMBLY MODELS WITH BACK BOX LENS FRAME ASSEMBLY STAN...

Page 5: ......

Page 6: ...rred to as R for right position and L for left position when looking at sensor in orientation shown in Fig 2 in which all switches are R See Fig 1 and 2 for each setting s corresponding switches Setting options for each category are noted in parenthesis below Factory Settings designated in bold for each category Detection Area Time Delay how long lamp remains on at 100 after last recognized motion...

Page 7: ... Green LED on antenna will flash slowly for 5 seconds and fixture will blink twice if done correctly Surrounding fc will be measured and recorded for 1 second Green LED on antenna and fixture will light for 10 sec onds to indicate successful fc recording Most recent fc measurement overwrites any prior DIP settings pg 1 and ambient lux overwrite eachother depending on latest action Scene Mode 100 d...

Page 8: ...or 30 for dimmed light output after time delay passes Note These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info e...

Reviews: