INSTRUCTIONS
FIELD-ADJUSTABLE FFLED® INSTALLATION
RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi cient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
CLEANING & MAINTENANCE
TROUBLESHOOTING
Note:
These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
FFLED FA-IN 1022
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2022 RAB LIGHTING Inc.
RAB WARRANTY:
RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
PINK
LIGHT
FIXTURE
Vaux 12V
YELLOW
GROUND
GROUND
( - ) DIM V
( + ) DIM V
COMMON
LINE
BLACK
WHITE
PURPLE
0-10V DIMMABLE WIRING
P-100091-RAB
Fig: 7
CAUTION: Be sure fi xture temperature is cool enough to
touch. Do not clean or maintain while fi xture is energized.
1.
Clean glass lens with non-abrasive glass cleaning solution.
2.
Do not open the fi xture to clean the LED. Do not touch the
LED.
1.
Check that the line voltage at the fi xture is correct. Refer to
wiring directions.
2.
Is the fi xture grounded properly?
3.
Is the photocell, if used, functioning properly?
Universal voltage driver permits operation at 120V through 277V,
50 or 60 Hz. Units ordered with
/480V
suffi x are 480V. For 0-10V
dimming follow the wiring directions as shown in Fig. 7.
1.
Connect the black fi xture lead to the
LINE
supply lead.
2.
Connect the white fi xture lead to the
COMMON
supply lead.
3.
Connect the
GROUND
wire from fi xture to supply ground.
4.
Connect the purple fi xture lead to the DIM V+ lead.
5.
Connect the pink fi xture lead to the DIM V- lead.
6.