WPLED104 INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

WPLED104

Standard (15 Deg)

WPLEDC104

Cutoff (7.5 Deg)

WPLEDFC104

Full Cutoff (0 Deg)

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

.

Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required 

for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 

FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough 

to touch.  Do not clean or maintain while fixture is 

energized.

1.  Clean glass lens & fixture with non-abrasive glass 

cleaning solution. 

2.  Do not open fixture to clean the LED. Do not touch the 

LED.

WPLED104 WALLMOUNT

RAB LIGHTING INC

9 JANUARY 2015

Wall Mount Box

Top Screws

Lower Screws

Close Up 

Plugs (4)

Gasket
Tether

Silicone 

Wiring Plug

Wall Mount Box 

Gasket

Key Hole Slot

Leveling 

Bubble

MOUNTING TO A WALL

1. 

Orient 

Wall Mount Box

 such that ‘TOP’ is pointing up. 

2. 

Feed supply wires through 

Wall Mount Box Gasket

 

into 

Wall Mount Box

 through 

Silicone Wiring Plug

, if 

not using conduit/ connectors. 

3. 

Secure 

Wall Mount Box

 to a sturdy mounting surface. 

Use appropriate mounting hardware such as lag bolts 

and anchors with washers suitable for the mounting 

surface. A 

Leveling Bubble

 is provided to level fixture.

4. 

Silicone around the edge of 

Wall Mount Box Gasket

 

and/ or junction box.

5. 

Check that 

Gasket

 is fully sealed.

6. 

Slide the stainless steel 

Tether

 from the fixture into the 

Key Hole Slot

 for hands free wiring.

7. 

Wire the fixture using UL listed wire connectors 

according to NEC and local codes. 

8. 

Place wired fixture over the 

Wall Mount Box

 and 

tighten the 

Top Screws

. Then tighten the 

Lower 

Screws

.

9. 

Tighten 

Close Up Plugs

 and apply weatherproof 

silicone sealant to all unused conduit entry points. 

CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened 

firmly. Apply weatherproof silicone sealant around the edge of the Wall Box and/or Junction Box. This is especially 

important with an uneven wall surface. Silicone all plugs and unused conduit entries.

4.58”

116.2mm

4.97”

126.3mm

1.30”

33mm

4.58”

116.2mm

4.97”

126.3mm