background image

WP4 INSTALLATION INSTRUCTIONS 

TROUBLESHOOTING 

1.  Is the proper lamp is installed? Check the wattage 

and ANSI code on the fixture label against markings 

on the lamp. Refer to Replacement Lamp table above 

for verification.

 

2. Make sure the lamp is not defective. Try a lamp 

known to be in operating condition. 

3. Check that the line voltage at fixture is correct.  

Refer to wiring directions. 

4. Is there voltage at the lamp socket?  If there is 

no voltage, check all connections 

5. Is the fixture grounded properly? 

6. Is the photocell functioning properly (if used)?

ACCESSORIES AND 

REPLACEMENT PARTS

Chrome Wire Guard:

    

GDWP3W

Door Frame & Glass:

   

GLWP3F (bronze)

 

 

 

 

GLWP3FW (white)

Factory Installed Photocell: 

“/PC” (120V)

 

 

 

 

“/PC2” (277V)

 

 

 

 

“/PCS” (Swivel 120V)

Quartz Restrike

 

“/QR” HID only 

Note:  These instructions do not cover all details or variations 

in equipment nor do they provide for every possible situation 

during installation, operation or maintenance.

WP4-IN-0811

REPLACEMENT LAMPS AND 

BALLASTS

 

Lamp 

ANSI Ballast 

Wattage 

Catalog# 

Code 

Catalog#

High Pressure Sodium

400 

LHPS400 

S51 

BHPSH400QT

Metal Halide

320 Pulse St  LMH320PSQ  M132 

BMHH320PSQ

350 Pulse St  LMH350PSQ  M131 

BMHH350PSQ 

400 Pulse St  LMH400PSQ  M135 

BMHH400PSQ

 

RAB fixture designs are protected under U.S. and International 

Intellectual Property laws.  Patent Pending.

LIGHT

FIXTURE

(+)LINE

BLACK

(-)COMMON WHITE

GROUND

GROUND

CLEANING & MAINTENANCE

 

CAUTION: Be sure fixture temperature is cool 

enough to touch.  Do not clean or maintain while 

fixture is energized. 

1.  Clean glass lens with non-abrasive glass cleaning 

solution. 

2.  As lamps age, light output diminishes. Mass  

relamping at regular intervals ensures full light output 

at the highest efficiency.

LAMP INSTALLATION

CAUTION: Prior to installing, check that the lamp is 

the correct ANSI type and wattage.  Observe lamp 

manufacturer’s recommendations on lamp operation, 

ballast type and burning positions. 

1.  Disconnect power. Make sure fixture and lamp are 

cool enough to touch. 

2.  Loosen 

Door Screws (2)  

from the door frame. A 

small rubber O-ring will retain screws.  Open door.  

3.  Fully insert lamp into socket. 

4.  Before closing door, make sure gasket is properly 

seated all around the backbox of the wallpack.  Close 

the door. Tighten 

Door Screws

.

Door 

Screws

WIRING SCHEMATIC

Reviews: