background image

9

Technical Tips:

Lights Do Not Turn On

Lights Turn Off Too Quickly

1. Check that lamps and fixtures 

work. Compare wiring to the 

Wiring Diagram

 in this manual. 

Check that the power is on.

2. If installing during daylight, 

remember that after power 
is turned on, the sensor will 
provide 5 minutes of Test Time. 
After 5 minutes, the sensor will 
switch to Automatic Mode and 
will not work during daylight if 
the photocell control is turned to 
night-only (moon) position.

If you require more than 5 minutes 
of Test Time, turn power off for at 
least 10 seconds and then turn power 
back on.

3. If you require the sensor to 

operate both day and night, 
turn the center control knob 
counterclockwise to the sun and 
moon symbol.

4. Check that lights from other 

sources, such as adjacent porch, 
garden, or streetlights, or lights 
from inside the house, are not in 
the sensor’s view. The sensor’s 
photocell may detect the light 
and deactivate. For operation at 
higher ambient light levels, turn 
the photocell control (center 
knob) toward the sun symbol.

5. Was sensor wired hot? If 

so, circuitry may have been 
damaged.

1. Check if the sensor is being 

“tricked” by reflected light. If 
lights controlled by the sensor 
shine or reflect into the photocell 
(located behind the lens), the 
unit will go on briefly, but then 
turn off, “thinking” it is daytime.

Solutions: 

• Adjust the photocell control 

(center knob) slightly 
counterclockwise to allow 
operation at higher ambient 
light levels

• Move the lights or reflectors
• Mask lens in the direction of the 

lights and/or reflections

2. Check if “R” lamps, non-reflector 

“A” lamps, or self-ballasted 
PL lamps are being used in a 
non-enclosed lampholder. If so, 
switch to reflector PAR floodlight 
lamps or Quartz floods so the 
sensor is not affected by stray 
light. If using PAR floodlights, 
consider using lower-wattage 
energy-saving lamps.

Problem:

Light

shining or 

reflecting

directly

into

photocell

Summary of Contents for Stealth STL200

Page 1: ...77 Specifications Switching Capacity Voltage Detection Pattern Time Adjustment Power Consumption Surge Protection UL Listing 8 amps 277 volts 1000 watts incandescent 50 x 200 5 seconds to 12 minutes 1 watt I E C specs Raintight Photoelectric Switch ...

Page 2: ...activations Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equiptment washer dryer or garagedoor openers Sensor must be below and as far as possible away from lights Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 12 feet high for optimum range and detection Mounting Plate STL200 F...

Page 3: ...off on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset to Automatic Mode Will STEALTH detect animals STEALTH may detect large animals Having animal trigger the sensor can give properties a lived in look However you can limit animal detection by turning down the sensitivity knob Sensitivity Increases or decreases the responsiveness a...

Page 4: ...daytime detections without turning on the lights Except during detections which trigger the controlled lights at night the LED remains on and serves as a deterrent indicating a security device in operation Red LED Detection Indicator How large of an area does STEALTH detect The standard lens detection pattern extends out 50 and is 200 wide The sensor may be swiveled in any direction to cover the a...

Page 5: ...it leads through holes in all gaskets and into junction box 4 Strip of insulation from all leads 5 Attach ground wire s to junction box grounding screw Connect as shown in wiring diagram pg 5 6 Twist on wire nuts Secure with electrical tape 7 Align EZ Plate and metal mounting plate to ensure proper seal Tighten EZ Plate center screw to attach EZ Plate to box making sure O Ring gasket is on the scr...

Page 6: ...e sensor To handle loads greater than 1 000 watts a qualified electrician should install a relay Switchplate Label Switchplate label has self adhesive backing Power Quality It is not recommended to install sensors on a circuit that also feeds motor loads such as HVAC equipt ment kitchen appliances or garage door openers The STEALTH circuit is surge and transient protected to IEC specifications How...

Page 7: ...until lights go on As distance from the sensor increases it will take more movement to be detected Aiming andWalkTesting Start Finish 3 Adjust the sensor aiming as needed to improve coverage 4 To adjust sensitivity turn knob gently Less sensitivity counter clockwise may be desired if you wish to detect a limited area or if the sensor is being activated by wind foliage or animals More sensitivity c...

Page 8: ...es properly with bag covering check item 4 7 Problem Sensor is triggered by unwanted movement or heat source Solution Aim sensor away from movement Mask lens in the direction of source Lower sensitivity control setting 3 Make sure sensor and lights are mounted firmly and do not move even slightly when touched If they move tighten all screws 4 Make sure sensor is not mounted on an unstable source s...

Page 9: ...Do not use with open par holders 5 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 6 Make sure sensor is not aimed within 20 ft of a road or sidewalk Passing cars will activate sensor Solution A 20ft safety zone and reduced sensitivity are recommended to avoid activation from passing cars 7 Heavy rain snow or high winds may acti...

Page 10: ...sensor s view The sensor s photocell may detect the light and deactivate For operation at higher ambient light levels turn the photocell control center knob toward the sun symbol 5 Was sensor wired hot If so circuitry may have been damaged 1 Check if the sensor is being tricked by reflected light If lights controlled by the sensor shine or reflect into the photocell located behind the lens the uni...

Page 11: ... allows maximum range Less Sensitive More Sensitive 10 TechnicalTips Range Appears Limited WRONG RIGHT 40 20 50 6 12 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Problem Sensor will not detect until movement crosses zones No ...

Page 12: ...g the sensor Create an Animal Alley by aiming sensor or masking the lower portion of the lens with opaque weather proof tape to reduce triggering 10 50 Animal Alley 4 Although it is surge and transient protected the sensor may occasionally turn on during extreme voltage surges 5 A possible source of mysterious sensor activations are strong local radio signals Check for nearby CB Ham VHF radio tran...

Page 13: ...he problem If your unit is out of warranty or the damage is unrelated to the original manufacture return your unit directly to us with a check for 30 00 made out to RAB Lighting We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damage...

Page 14: ... with Green Ground Screw Hanging Hook 1 2 Close Up Plugs 3 Slotted Screws 4 Finishing Cap O ring Gasket Center Mounting Screws CU4 Plate Metal Plate 13 Metal CU4 STL200 277 Indoor Switchplate Label Wire Nuts 3 Lens Mask 2 ...

Page 15: ... Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com STL200 277V IN 1016 ...

Page 16: ...FOR WET LOCATIONS Specifications Switching Capacity Voltage Detection Pattern Time Adjustment Power Consumption Surge Protection UL Listing 8 amps 120 volts 300W on LED fixture 50 x 2000 5 seconds to 12 minutes 1 watt I E C specs Raintight Photoelectric Switch ...

Page 17: ...rician can install a relay Line Carrier Remote Control Systems such as X 10 Levitron or Radio Shack are incompatible with sensors and cause false activations Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equiptment washer dryer or garagedoor openers Sensor must be below and as far as possible away from lights Sensor functions best when the direction of exp...

Page 18: ...off on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset to Automatic Mode Will STEALTH detect animals STEALTH may detect large animals Having animal trigger the sensor can give properties a lived in look However you can limit animal detection by turning down the sensitivity knob Sensitivity Increases or decreases the responsiveness a...

Page 19: ...ytime detections without turning on the lights Except during detections which trigger the controlled lights at night the LED remains on and serves as a deterrent indicating a security device in operation Red LED Detection Indicator How large of an area does STEALTH detect The standard lens detection pattern extends out 50 and is 200 wide The sensor may be swiveled in any direction to cover the are...

Page 20: ...le sensor To handle loads greater than 300 watts a qualified electrician should install a relay Switchplate Label Switchplate label has self adhesive backing Power Quality It is not recommended to install sensors on a circuit that also feeds motor loads such as HVAC equipt ment kitchen appliances or garage door openers The STEALTH circuit is surge and transient protected to IEC specifications Howe...

Page 21: ...until lights go on As distance from the sensor increases it will take more movement to be detected Aiming andWalkTesting Start Finish 3 Adjust the sensor aiming as needed to improve coverage 4 To adjust sensitivity turn knob gently Less sensitivity counter clockwise may be desired if you wish to detect a limited area or if the sensor is being activated by wind foliage or animals More sensitivity c...

Page 22: ... the sensor Create an Animal Alley by aiming sensor or masking the lower portion of the lens with opaque weather proof tape to reduce triggering 10 50 Animal Alley 4 Although it is surge and transient protected the sensor may occasionally turn on during extreme voltage surges 5 A possible source of mysterious sensor activations are strong local radio signals Check for nearby CB Ham VHF radio trans...

Page 23: ...es properly with bag covering check item 4 7 Problem Sensor is triggered by unwanted movement or heat source Solution Aim sensor away from movement Mask lens in the direction of source Lower sensitivity control setting 3 Make sure sensor and lights are mounted firmly and do not move even slightly when touched If they move tighten all screws 4 Make sure sensor is not mounted on an unstable source s...

Page 24: ...Do not use with open par holders 5 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 6 Make sure sensor is not aimed within 20 ft of a road or sidewalk Passing cars will activate sensor Solution A 20ft safety zone and reduced sensitivity are recommended to avoid activation from passing cars 7 Heavy rain snow or high winds may acti...

Page 25: ...sensor s view The sensor s photocell may detect the light and deactivate For operation at higher ambient light levels turn the photocell control center knob toward the sun symbol 5 Was sensor wired hot If so circuitry may have been damaged 1 Check if the sensor is being tricked by reflected light If lights controlled by the sensor shine or reflect into the photocell located behind the lens the uni...

Page 26: ...Mounting 6 12ft allows maximum range 10 TechnicalTips Range Appears Limited WRONG RIGHT 40 20 50 6 12 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Problem Sensor will not detect until movement crosses zones No detection until...

Page 27: ...problem If your unit is out of warranty or the damage is unrelated to the original manufacture return your unit directly to us with a check for 30 00 made out to RAB Lighting We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages w...

Page 28: ...l Wire Nuts 3 Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com STL200LED IN 0616 ...

Page 29: ...BLE FOR WET LOCATIONS Specifications Switching Capacity Voltage Detection Pattern Time Adjustment Power Consumption Surge Protection UL Listing 8 amps 277 volts 300W on LED fixture 50 x 2000 5 seconds to 12 minutes 1 watt I E C specs Raintight Photoelectric Switch ...

Page 30: ...rician can install a relay Line Carrier Remote Control Systems such as X 10 Levitron or Radio Shack are incompatible with sensors and cause false activations Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equiptment washer dryer or garagedoor openers Sensor must be below and as far as possible away from lights Sensor functions best when the direction of exp...

Page 31: ...off on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset to Automatic Mode Will STEALTH detect animals STEALTH may detect large animals Having animal trigger the sensor can give properties a lived in look However you can limit animal detection by turning down the sensitivity knob Sensitivity Increases or decreases the responsiveness a...

Page 32: ...daytime detections without turning on the lights Except during detections which trigger the controlled lights at night the LED remains on and serves as a deterrent indicating a security device in operation Red LED Detection Indicator How large of an area does STEALTH detect The standard lens detection pattern extends out 50 and is 200 wide The sensor may be swiveled in any direction to cover the a...

Page 33: ...le sensor To handle loads greater than 300 watts a qualified electrician should install a relay Switchplate Label Switchplate label has self adhesive backing Power Quality It is not recommended to install sensors on a circuit that also feeds motor loads such as HVAC equipt ment kitchen appliances or garage door openers The STEALTH circuit is surge and transient protected to IEC specifications Howe...

Page 34: ...until lights go on As distance from the sensor increases it will take more movement to be detected Aiming andWalkTesting Start Finish 3 Adjust the sensor aiming as needed to improve coverage 4 To adjust sensitivity turn knob gently Less sensitivity counter clockwise may be desired if you wish to detect a limited area or if the sensor is being activated by wind foliage or animals More sensitivity c...

Page 35: ... the sensor Create an Animal Alley by aiming sensor or masking the lower portion of the lens with opaque weather proof tape to reduce triggering 10 50 Animal Alley 4 Although it is surge and transient protected the sensor may occasionally turn on during extreme voltage surges 5 A possible source of mysterious sensor activations are strong local radio signals Check for nearby CB Ham VHF radio trans...

Page 36: ...es properly with bag covering check item 4 7 Problem Sensor is triggered by unwanted movement or heat source Solution Aim sensor away from movement Mask lens in the direction of source Lower sensitivity control setting 3 Make sure sensor and lights are mounted firmly and do not move even slightly when touched If they move tighten all screws 4 Make sure sensor is not mounted on an unstable source s...

Page 37: ...Do not use with open par holders 5 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 6 Make sure sensor is not aimed within 20 ft of a road or sidewalk Passing cars will activate sensor Solution A 20ft safety zone and reduced sensitivity are recommended to avoid activation from passing cars 7 Heavy rain snow or high winds may acti...

Page 38: ...sensor s view The sensor s photocell may detect the light and deactivate For operation at higher ambient light levels turn the photocell control center knob toward the sun symbol 5 Was sensor wired hot If so circuitry may have been damaged 1 Check if the sensor is being tricked by reflected light If lights controlled by the sensor shine or reflect into the photocell located behind the lens the uni...

Page 39: ...Mounting 6 12ft allows maximum range 10 TechnicalTips Range Appears Limited WRONG RIGHT 40 20 50 6 12 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Problem Sensor will not detect until movement crosses zones No detection until...

Page 40: ...problem If your unit is out of warranty or the damage is unrelated to the original manufacture return your unit directly to us with a check for 30 00 made out to RAB Lighting We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages w...

Page 41: ...l Wire Nuts 3 Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com STL200LED 277V IN 0216 ...

Page 42: ...FOR WET LOCATIONS Specifications Switching Capacity Voltage Detection Pattern Time Adjustment Power Consumption Surge Protection UL Listing 8 amps 120 volts 300W on LED fixture 50 x 2000 5 seconds to 12 minutes 1 watt I E C specs Raintight Photoelectric Switch ...

Page 43: ...rician can install a relay Line Carrier Remote Control Systems such as X 10 Levitron or Radio Shack are incompatible with sensors and cause false activations Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equiptment washer dryer or garagedoor openers Sensor must be below and as far as possible away from lights Sensor functions best when the direction of exp...

Page 44: ...off on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset to Automatic Mode Will STEALTH detect animals STEALTH may detect large animals Having animal trigger the sensor can give properties a lived in look However you can limit animal detection by turning down the sensitivity knob Sensitivity Increases or decreases the responsiveness a...

Page 45: ...ytime detections without turning on the lights Except during detections which trigger the controlled lights at night the LED remains on and serves as a deterrent indicating a security device in operation Red LED Detection Indicator How large of an area does STEALTH detect The standard lens detection pattern extends out 50 and is 200 wide The sensor may be swiveled in any direction to cover the are...

Page 46: ...le sensor To handle loads greater than 300 watts a qualified electrician should install a relay Switchplate Label Switchplate label has self adhesive backing Power Quality It is not recommended to install sensors on a circuit that also feeds motor loads such as HVAC equipt ment kitchen appliances or garage door openers The STEALTH circuit is surge and transient protected to IEC specifications Howe...

Page 47: ...until lights go on As distance from the sensor increases it will take more movement to be detected Aiming andWalkTesting Start Finish 3 Adjust the sensor aiming as needed to improve coverage 4 To adjust sensitivity turn knob gently Less sensitivity counter clockwise may be desired if you wish to detect a limited area or if the sensor is being activated by wind foliage or animals More sensitivity c...

Page 48: ... the sensor Create an Animal Alley by aiming sensor or masking the lower portion of the lens with opaque weather proof tape to reduce triggering 10 50 Animal Alley 4 Although it is surge and transient protected the sensor may occasionally turn on during extreme voltage surges 5 A possible source of mysterious sensor activations are strong local radio signals Check for nearby CB Ham VHF radio trans...

Page 49: ...es properly with bag covering check item 4 7 Problem Sensor is triggered by unwanted movement or heat source Solution Aim sensor away from movement Mask lens in the direction of source Lower sensitivity control setting 3 Make sure sensor and lights are mounted firmly and do not move even slightly when touched If they move tighten all screws 4 Make sure sensor is not mounted on an unstable source s...

Page 50: ...Do not use with open par holders 5 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 6 Make sure sensor is not aimed within 20 ft of a road or sidewalk Passing cars will activate sensor Solution A 20ft safety zone and reduced sensitivity are recommended to avoid activation from passing cars 7 Heavy rain snow or high winds may acti...

Page 51: ...sensor s view The sensor s photocell may detect the light and deactivate For operation at higher ambient light levels turn the photocell control center knob toward the sun symbol 5 Was sensor wired hot If so circuitry may have been damaged 1 Check if the sensor is being tricked by reflected light If lights controlled by the sensor shine or reflect into the photocell located behind the lens the uni...

Page 52: ...Mounting 6 12ft allows maximum range 10 TechnicalTips Range Appears Limited WRONG RIGHT 40 20 50 6 12 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Problem Sensor will not detect until movement crosses zones No detection until...

Page 53: ...problem If your unit is out of warranty or the damage is unrelated to the original manufacture return your unit directly to us with a check for 30 00 made out to RAB Lighting We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages w...

Page 54: ...l Wire Nuts 3 Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com STL200LED IN 0616 ...