Location Considerations:

• Choose a location from which the sensor 

can “see” all the paths of movement that 
will be illuminated by its lights.

• SmartBox may be painted to blend in 

with walls. Carefully apply masking tape 
to the sensor lens or use the Lens Mask 
Kit provided before painting.

• Sensor functions best when the direction 

of expected movement is across its 
detection pattern, not towards the 
sensor.

• If wall mounting, locate 5-8’ high for 

optimum range. Lower mounting height 
will reduce range.

Test Period:

The sensor has a 3-minute Test Period 

which allows it to be aimed and walk 
tested day or night.

• For the first 30 seconds, the lights will be 

turned on. During this time, test that all 
fixtures and lamps function properly.

• For the next 3 minutes, the sensor will 

keep lights on for 5 seconds each time 
it detects movement in its Detection 
Zone. The sensor will change to 
Automatic Mode after the 3 minute Test 
Period.

• If another 3 minute Test Period is desired, 

turn the power off for at least 10 
seconds and back on again.

Walk Test:

The purpose of the Walk Test is to check 

and adjust the coverage pattern.

1. Aim the sensor approximately to cover 

the area you desire. 

2. Start outside the Detection Zone and 

walk across the zone until the lights 
go on. As distance from the sensor 
increases, it will take more movement 
to be detected. For instance, at 10 feet, a 
half step will be enough, while at 30 feet, 
several steps will be necessary.

Picking A Location

Detection Pattern:

• The sensor has a “Double Look Down” 

Lens with one “Look Out” zone and 
two “Look Down” zones, for excellent 
detection both at long and close range

• Detection extends out a maximum of 40 

feet and is 180º wide.

• To reduce the Detection Pattern length, 

adjust the tilt set screw underneath the 
sensor using the hex wrench provided.

• To reduce Detection Pattern width, mask 

the sides of the lens with the Lens Mask 
Kit provided or opaque weatherproof 
tape.

• If sensor is mounted by a doorway at the 

top of stairs, be aware that the elevated 
mounting height may extend the 
sensors range.

Aiming and Walk Testing

S

T

8’

Side View

30’

Double Look Down Lens

60’

30’

Photocell

Turn to moon  

symbol for night 

only

Turn to sun 

symbol for 24 

hour operation 

(lights turn on 

night and day)

3. To reduce range, use the lens masks 

provided or tilt sensor down.Repeat 
steps #2 and #3 until you are satisfied 
with the coverage. 

4. The Time Control is factory set between 

5-8 minutes. This period starts after 
the movement in the Detection Zone 
ceases. If less time is desired, turn the 
time control counterclockwise. For 
more time, turn the control clockwise.

5. The sensor is factory set for night only 

operation. To obtain full operation 
24 hours per day, turn the Photocell 
Control fully clockwise to the sun 
symbol. Intermediate settings will allow 
the sensor to operate earlier or later at 
dusk.

6. Your sensor is ready for operation. See 

the Technical Tips pages if additional 
help is needed.

Control Panel:
Turn controls gently using the adjustment 
tool provided. Do not force past stops.

Top View

9

8

Start

Finish

Summary of Contents for SmartBox

Page 1: ...Installation Manual SmartBox Outdoor Motion Sensor It s easy to add motion detection to outdoor lights ...

Page 2: ...s Hard lens resists casual vandalism Case Construction Precision molded Lexan Color Matched Lens Dark lens with black units White lens with white units Surge Protection Withstands up to 3000 Volts Manual Override Double flip wall switch logic prevents activation by short power outages Resets to auto at dawn No extra wiring needed LED Detection Indicator Glows red day and night for on guard deterre...

Page 3: ...6 high for optimum range and direction Less Sensitive More Sensitive Assembly and Wiring 1 SmartBox requires a vertically mounted single gang full size outlet box 2 Position gasket on back of switch plate 3 Bring power leads and sensor leads into box 4 Attached ground wire s to outlet box grounding screw 5 Strip 1 2 of insulation from all leads Connect as shown in Wiring Diagram 6 Twist on wire nu...

Page 4: ...ity and Photocell adjusted TimeControl Sets the time that lights will remain on after the Detection Zone is vacated from approximately 5 seconds to 15 minutes Use the adjustment tool provided to turn clockwise to increase the time Factory Setting 5 8 minutes Photocell Control For night only operation use the tool provided or a small screwdriver to turn the Photocell Control all the way counter clo...

Page 5: ...ll be necessary Picking A Location Detection Pattern The sensor has a Double Look Down Lens with one Look Out zone and two Look Down zones for excellent detection both at long and close range Detection extends out a maximum of 40 feet and is 180º wide To reduce the Detection Pattern length adjust the tilt set screw underneath the sensor using the hex wrench provided To reduce Detection Pattern wid...

Page 6: ...om lights 1 Make sure sensor is not aimed at something that would move or change temperature such as waving branches water air conditioners windows or heating vents even on neighboring property You can test for infrared sources in the area by placing a box or bag over the sensor Put sensor into Test Mode After the initial 30 seconds of the lights being on lights should stay off Wave your hand insi...

Page 7: ...en lights streetlights or lights from inside the house are not in the sensor s view See 1 under Lights Turn Off Too Quickly 4 Was sensor wired hot If so circuitry may have been damaged 5 If sensor is painted make sure there is no paint on the lens and that the lens paint mask is removed 5 Make sure lights are not visible from or reflecting back into sensor Check for white or reflective surfaces cl...

Page 8: ...ct was purchased by the contractor or end user from an authorized RAB distributor who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a licensed electrician and the product was in its original unopened and new condition at the time of installation RAB LIG...

Page 9: ... Answers rablighting com Visit our website for product info Tech Help Line 888 722 1000 e mail sales rablighting com Free Lighting Layouts Answered online or by request 2019 RAB LIGHTING Inc Northvale New Jersey 07647 USA ...