background image

Installation Step by Step

1. 

Remove the existing switch, if

necessary.

2. 

Connect as shown in the wiring

diagrams. See page 3.

3. 

Twist on wire nuts. Secure with

electrical tape. Mount LOS800 in

wall box with two screws provided.

4. 

Place switch in OFF position

before turning on power.

5. 

Press the Auto/Off switch IN to

“Auto”. After a short delay, the

lights will turn ON. When the room

is vacated, the lights will turn OFF

after the time delay you set.

6. 

See “Adjustments” section for

control options. Only make adjust-

ments after a 3 minute warmup

period.

7. 

Attach the wall plate.

Installation

2

WALL MOUNTING BOX

ADJUSTMENT 

ACCESS COVER

(Removable only

when switch plate

is off)

Black

Red

White

Black

Caution:

• TURN OFF ALL POWER BY

REMOVING THE POWER FUSES

OR TURNING OFF THE CIRCUIT

BREAKER FOR YOUR SAFETY

AND TO PREVENT DAMAGE TO

THE UNIT.

• Please read this entire Owner’s

Manual before installing.

• All wiring should comply with

local electrical codes and requires 

a qualified electrician.

• Make sure the total lighting load

connected to the LOS800 does not

exceed the following:

120v: 800w Incandescent & 

Fluorescent

277v: 1200w Incandescent & 

Fluorescent

Exceeding the wattage limits may

damage the unit. To switch more

wattage, an electrician can install a

relay to handle the load.

• Do not use LOS800 to control

high intensity discharge lights,

fans, heaters or motors. Small

bathroom exhaust fans may be

used with LOS800.

• The LOS800 may be used with

both standard and electronic 

fluorescent ballasts.

Basic Wiring Diagram

Single Level Lighting

Multiple Level Lighting 

Wiring Diagram

Caution:

• TURN OFF ALL POWER BY

REMOVING THE POWER FUSES

OR TURNING OFF THE CIRCUIT

BREAKER FOR YOUR SAFETY

AND TO PREVENT DAMAGE TO

THE UNIT.

• The supply ground wire must be

tightly secured to ground.

3-way Switch wiring Diagram

Wiring Diagrams

3

COMMON (WHITE)

HOT (BLACK)

LOAD

RED

RED

BLACK

BLACK

RED

RED

BLACK

BLACK/HOT

WHITE/COMMON

COMMON (WHITE)

HOT (BLACK)

LOAD

LOAD

LOAD

LOAD

4

5

Summary of Contents for LOS800

Page 1: ...ltiple sensors Superb small movement sensitivity within 18 feet Great for sedentary office use No dead spots with 18 sensing fingers Easy Installation Works with electronic ballasts No minimum load requirement Replaces single pole wall switches without additional wiring Decorator style rectangular switchplate included Only 1 2 protrusion from switch plate No adjustments required for most installat...

Page 2: ...eight is 3 5 to 4 5 feet above the floor If people cannot see the sensor lens from their normal positions in the room the sensor will not detect their presence High cabinets walls doors and other obstructions may limit the sensor s view of the entire room If obstructions can be moved the sensor will have a better view If the areas obstructed are not areas normally occupied the sensor will still be...

Page 3: ...efore installing All wiring should comply with local electrical codes and requires a qualified electrician Make sure the total lighting load connected to the LOS800 does not exceed the following 120v 800w Incandescent Fluorescent 277v 1200w Incandescent Fluorescent Exceeding the wattage limits may damage the unit To switch more wattage an electrician can install a relay to handle the load Do not u...

Page 4: ...screwdriver for more time delay Hole for Coverplate screw Over tightening screw will strip threads 5 6 Lights do Not Turn On 1 Check that the lamps and fixtures work wiring exactly matches the wiring diagram wiring polarity is correct power is on sensor has warmed up for 3 minutes off auto switch is not OFF 2 Make sure sensor s view of the room is not blocked Lights do Not Turn Off 1 Check that th...

Page 5: ...lem If your unit is out of warranty or the damage is unrelated to its original manufacture return your unit directly to RAB with a check for 20 00 payable to RAB Lighting We will repair or replace the unit Under no circumstances shall we be liable for any incidental or con sequential damages arising out of or in connection with the use or performance of this product or other indirect damages with ...

Reviews: