background image

SMART SWITCH OCCUPANCY SENSOR

Installation Manual

Features

Maximum Energy savings

• 

Sensitive 180

º

view passive

infrared motion detector keeps 

lights on only when rooms are in

use.

No ON switch so lights are never

left on by mistake.

Meets California Title 24 standards.

Suitable for all utility rebate 

programs

Maximum Coverage

• 

180

º

wide angle detection pattern

Picks up people entering door-

ways quickly with standard next   

to doorway location.

Covers 1000 square feet, eliminates

needs for multiple sensors.

Superb small movement sensitivity

within 18 feet. Great for sedentary

office use.

No dead spots with 18 sensing 

fingers.

Easy Installation

• 

Works with electronic ballasts.

No minimum load requirement.

Replaces single pole wall switches

without additional wiring.

Decorator style, rectangular 

switchplate included.

Only 1/2” protrusion from switch 

plate.

No adjustments required for most 

installations.

• 

Compact design fits standard 

switch boxes with plenty of room   

for wiring.

Tamperproof control panel cover

reduces call backs for tampering.

Maximum Versatility

• 

Switches all types of fluorescent

and/or incandescent lighting.

Fits single or multi-gang locations

without special adapters.

1

Summary of Contents for LOS800

Page 1: ...ltiple sensors Superb small movement sensitivity within 18 feet Great for sedentary office use No dead spots with 18 sensing fingers Easy Installation Works with electronic ballasts No minimum load requirement Replaces single pole wall switches without additional wiring Decorator style rectangular switchplate included Only 1 2 protrusion from switch plate No adjustments required for most installat...

Page 2: ...eight is 3 5 to 4 5 feet above the floor If people cannot see the sensor lens from their normal positions in the room the sensor will not detect their presence High cabinets walls doors and other obstructions may limit the sensor s view of the entire room If obstructions can be moved the sensor will have a better view If the areas obstructed are not areas normally occupied the sensor will still be...

Page 3: ...efore installing All wiring should comply with local electrical codes and requires a qualified electrician Make sure the total lighting load connected to the LOS800 does not exceed the following 120v 800w Incandescent Fluorescent 277v 1200w Incandescent Fluorescent Exceeding the wattage limits may damage the unit To switch more wattage an electrician can install a relay to handle the load Do not u...

Page 4: ...screwdriver for more time delay Hole for Coverplate screw Over tightening screw will strip threads 5 6 Lights do Not Turn On 1 Check that the lamps and fixtures work wiring exactly matches the wiring diagram wiring polarity is correct power is on sensor has warmed up for 3 minutes off auto switch is not OFF 2 Make sure sensor s view of the room is not blocked Lights do Not Turn Off 1 Check that th...

Page 5: ...lem If your unit is out of warranty or the damage is unrelated to its original manufacture return your unit directly to RAB with a check for 20 00 payable to RAB Lighting We will repair or replace the unit Under no circumstances shall we be liable for any incidental or con sequential damages arising out of or in connection with the use or performance of this product or other indirect damages with ...