Before to proceed, check the test resistors values in according to the amplifier type that is
used (in this case the type is VJ8000-TR that uses Yu148 tube, see as reference TABLE D
and FIG. 39). Since, the protections intervention on the equipment is set at 3.9 V, is
necessary that at maximum voltage or current value of the tube corresponds to 3.9 V, to
allow the protections intervention.
Example:
A value for VJ8000-TR, tree-phases version, with Yu148 tube. IA max set to 1.6 A
corresponds to 3.9 V on the TP6 test point output. In this way if the current exceeds 1.6 A
value the protections intervene.In the manual there is a table with all input and output
voltage of the card.
IA = 2,5 A
Ig = 500 mA
VF = 7 VAC
If = 78 A
ROS o RFL = 1000 W
4.3) MEASURES CARD ADJUSTING OPERATIONS
Adjusting procedure of the card at first switch on of the equipment in case of card
replacement.
The first operation that must be executed is that to calibrate the card reference voltage (3.9
V), using P15 trimmer.
To measure it using a multimeter connect the negative to ground and the positive to TP9 test
point.