10. Telemetry Card Option
10.1 Calibration of the Voltages on the Telemetry connector
The VJs internal Telemetry connector gives to the external the voltages referred
to the various values under control. The voltage related to the Forward Power
output is 1,6V for 1KW. To calibrate this voltage follow the procedure below:
1-
Adjust the power of the machine to the nominal value of 1KW.
2-
Adjust R13 on the Telemetry Card to obtain a voltage, between pin 16 and
pin 1 of Telemetry connector, of 1,6V.
The pin 4 gives the voltage referred to measurment of the Reflected Power. This
voltage is 1,4V for 100W (10% of 1KW). To calibrate this voltage follow the
procedure below:
1-
Adjust the Reflected Power to 100W using a wattmeter Bird in output.
2-
Adjust R14 of Telemetry Card to obtain a voltage, between pin 14 and pin 1
of connector, of 1,4V.
3-
Adjust R36 to set the Power Good threshold.
10.2 Wiring Connections details
1- The exciter is not supplied from the Service Connector but separataly. This is
because if there was no high voltage, the Service Connector would be not
supplies instead, too. The exciter shall be ever ON.
2- A system that closes to earth a BNC contact when the machine is in Standby
mode is used. This contact is connected with a BNC-BNC cable to the Interlock/
RF Mute connector of the exciter. When the VJ goes in Standby status, the
exciter enters in RF Mute mode. The contact that permits this functionallity is
located on the Service teleswitch.
3- A Reset (or Restart) button is connected between pin 9 and earth of Telemetry
Card JP2 connector and its located on the front panel. Its used to give the
same kind of signal as the an exciter that an PTXLCD gives when it is switches
ON. This operation resets the alarms and the remote control relay, in case the
amplifier is in OFF status and there is not an exciter able to change it to the ON
status.
4- The Alarms Card is supplied by the alternate current that first passes throught
JP3 (pin 1 and 2) of telemetry. When the Telemetry Card receives the REMOTE
OFF command, Alarms Card turns OFF itself. This permits to remotly reset the
alarms throught an ON-OFF-ON sequency. Please remember that after 6
attempts failed the machine will block itself. This remote control system gives
a remote reactivation mechanism.
5- A green LED is mounted between the point S of the Alarm Card and ground
(throught a 2K2 resistor); this is to indicate whether the Alarms Cards is supplied
or not.
Summary of Contents for VJ2000
Page 1: ...Prodotto da Italia VJ2000 User Manual...
Page 4: ...This page intentionally left blank...
Page 21: ...VJ2000 15 44 USER MANUAL Rev 4 0 26 02 01 FIG 1...
Page 23: ...VJ2000 17 44 USER MANUAL Rev 4 0 26 02 01 FIG 2...
Page 25: ...VJ2000 19 44 USER MANUAL Rev 4 0 26 02 01 FOTO 1 3 1 2 5 7 11 9 4 6 8 12 10...
Page 27: ...VJ2000 21 44 USER MANUAL Rev 4 0 26 02 01 FOTO 2 1 2 3 6 5 4...
Page 29: ...VJ2000 23 44 USER MANUAL Rev 4 0 26 02 01 FOTO 3 10 11 8 3 9 1 2 7 6 5 4...
Page 43: ...VJ2000 37 44 USER MANUAL Rev 4 0 26 02 01 SETUP 3 FIG 3...
Page 44: ...VJ2000 38 44 USER MANUAL Rev 4 0 26 02 01 SETUP 4 FIG 4...
Page 45: ...VJ2000 39 44 USER MANUAL Rev 4 0 26 02 01 SETUP 5 FIG 5...
Page 46: ...VJ2000 40 44 USER MANUAL Rev 4 0 26 02 01 SETUP 6 FIG 6...
Page 51: ...VJ2000 Flat Cable 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 53: ...VJ2000 Telemetry Cable 1 2 Appendice Tecnica Rev 1 1 26 02 01...
Page 55: ...VJ2000 Power Supply 1 ph 1 6 Appendice Tecnica Rev 1 0 26 02 01...
Page 56: ...VJ2000 2 6 Power Supply 1 ph Technical Appendix Rev 1 0 26 02 01...
Page 61: ...VJ2000 H T R Card 1 phase 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 62: ...VJ2000 2 4 H T R Card 1 phase Technical Appendix Rev 1 0 26 02 01...
Page 65: ...VJ2000 R F Block 1 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 69: ...VJ2000 Power Supply 3 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 70: ...VJ2000 2 4 Power Supply 3 ph Technical Appendix Rev 1 0 26 02 01...
Page 73: ...VJ2000 H T R Card 3 phase 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 75: ...VJ2000 R F Block 3 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 80: ...VJ2000 2 4 Alarms Card Technical Appendix Rev 1 0 26 02 01...
Page 84: ...VJ2000 2 4 Gride Plate Meter Technical Appendix Rev 1 0 26 02 01...
Page 88: ...VJ2000 2 4 H V M Voltmeter Technical Appendix Rev 1 0 26 02 01...
Page 92: ...VJ2000 2 4 Plate V M Card Technical Appendix Rev 1 0 26 02 01...
Page 96: ...VJ2000 2 4 Low Pass Filter Technical Appendix Rev 1 0 26 02 01...
Page 99: ...VJ2000 Input Matching Circuit 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 100: ...VJ2000 2 4 Input Matching Circuit Technical Appendix Rev 1 0 26 02 01...
Page 104: ...VJ2000 2 4 Directional Coupler Technical Appendix Rev 1 0 26 02 01...
Page 107: ...VJ2000 Telemetry Card opt 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 108: ...VJ2000 2 4 Telemetry Card opt Technical Appendix Rev 1 0 26 02 01...