VJ2000
32 / 44
USER MANUAL
Rev. 4.0 - 26/02/01
10) With output power at 2000 W, make small adjustments, as above, to minimize grid and
anode currents; if necessary, reduce exciter power to maintain 2000 W of output power.
8.2 Calibration of the Protection Board
Before calibrating the protection board, or IG and IA currents, remove the front panel
which also supports the RF chamber.
Disconnect the antenna output cable, remove the coaxial cable from the input connector,
undo the 8 screws holding the panel and remove the panel; take care not to disturb the high
voltage cables and the multipolar service cable.
Lay the chamber carefully on a raised surface, opposite the unit to facilitate the following
procedure.
The protection board has three trimmers for adjusting the following alarm thresholds:
insufficient fan pressure, excess V.S.W.R. and excess grid current.
These alarm conditions are indicated by three leds (Alarms Fig.1).
Remove the metal cover of the protection box by undoing the 4 screws.
The alarm thresholds may be calibrated through the following procedure:
1)
CALIBRATION OF FAN PRESSURE ALARM THRESHOLD (PRESS.).
a)
Switch the ST.BY. switch (19 Fig.1) to ST.BY.
b)
Enable power to the unit by switching the POWER switch (18 Fig.1) to ON.
c)
Ensure that the PRESS. indicator (15 Fig.1), initially on, turns off when the air-flow
switch (3 Photo 2), positioned inside the flue, switches up (air pressure normal).
Two error conditions can prevent the above sequence from being completed: the indicator
remains on, or remains permanently off.
In this case adjust the trimmer, R4, until the sequence is completed correctly: switch
down, led on; switch up, led off.
2)
CALIBRATION OF V.S.W.R.
To adjust the threshold of the V.S.W.R. alarm first perform SETUP 1.
The threshold should be set at around 10 % of the maximum output power i.e. between
170 and 200W.
a)
Connect a mismatched, dummy load (e.g. 2.0KW/50 Ohm in parallel) to the RF output
of the amplifier, in series with a bypass wattmeter.
b)
With the unit switched on (N.B. the rear cover must be in place) and having calibrated
the unit to its exciter frequency, gradually increase the output power from 0W until a
reflected power of 170/200W is registered on the external wattmeter.
c)
Adjust the trimmer R7 until the alarm threshold is reached and the V.S.W.R. led lights
up (13 Fig.1).
N.B. Several attempts may be necessary. At least 60 seconds should be allowed
inbetween attempts to allow an automatic reset.
Summary of Contents for VJ2000
Page 1: ...Prodotto da Italia VJ2000 User Manual...
Page 4: ...This page intentionally left blank...
Page 21: ...VJ2000 15 44 USER MANUAL Rev 4 0 26 02 01 FIG 1...
Page 23: ...VJ2000 17 44 USER MANUAL Rev 4 0 26 02 01 FIG 2...
Page 25: ...VJ2000 19 44 USER MANUAL Rev 4 0 26 02 01 FOTO 1 3 1 2 5 7 11 9 4 6 8 12 10...
Page 27: ...VJ2000 21 44 USER MANUAL Rev 4 0 26 02 01 FOTO 2 1 2 3 6 5 4...
Page 29: ...VJ2000 23 44 USER MANUAL Rev 4 0 26 02 01 FOTO 3 10 11 8 3 9 1 2 7 6 5 4...
Page 43: ...VJ2000 37 44 USER MANUAL Rev 4 0 26 02 01 SETUP 3 FIG 3...
Page 44: ...VJ2000 38 44 USER MANUAL Rev 4 0 26 02 01 SETUP 4 FIG 4...
Page 45: ...VJ2000 39 44 USER MANUAL Rev 4 0 26 02 01 SETUP 5 FIG 5...
Page 46: ...VJ2000 40 44 USER MANUAL Rev 4 0 26 02 01 SETUP 6 FIG 6...
Page 51: ...VJ2000 Flat Cable 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 53: ...VJ2000 Telemetry Cable 1 2 Appendice Tecnica Rev 1 1 26 02 01...
Page 55: ...VJ2000 Power Supply 1 ph 1 6 Appendice Tecnica Rev 1 0 26 02 01...
Page 56: ...VJ2000 2 6 Power Supply 1 ph Technical Appendix Rev 1 0 26 02 01...
Page 61: ...VJ2000 H T R Card 1 phase 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 62: ...VJ2000 2 4 H T R Card 1 phase Technical Appendix Rev 1 0 26 02 01...
Page 65: ...VJ2000 R F Block 1 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 69: ...VJ2000 Power Supply 3 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 70: ...VJ2000 2 4 Power Supply 3 ph Technical Appendix Rev 1 0 26 02 01...
Page 73: ...VJ2000 H T R Card 3 phase 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 75: ...VJ2000 R F Block 3 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 80: ...VJ2000 2 4 Alarms Card Technical Appendix Rev 1 0 26 02 01...
Page 84: ...VJ2000 2 4 Gride Plate Meter Technical Appendix Rev 1 0 26 02 01...
Page 88: ...VJ2000 2 4 H V M Voltmeter Technical Appendix Rev 1 0 26 02 01...
Page 92: ...VJ2000 2 4 Plate V M Card Technical Appendix Rev 1 0 26 02 01...
Page 96: ...VJ2000 2 4 Low Pass Filter Technical Appendix Rev 1 0 26 02 01...
Page 99: ...VJ2000 Input Matching Circuit 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 100: ...VJ2000 2 4 Input Matching Circuit Technical Appendix Rev 1 0 26 02 01...
Page 104: ...VJ2000 2 4 Directional Coupler Technical Appendix Rev 1 0 26 02 01...
Page 107: ...VJ2000 Telemetry Card opt 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 108: ...VJ2000 2 4 Telemetry Card opt Technical Appendix Rev 1 0 26 02 01...