TEX150-LCD/S
10 / 24
User Manual
Rev. 1.0 - 09/07/04
5.4.1 Function menu (Fnc)
From this menu you can set the deviation
display mode
, enable or disable
power
delivery
by the exciter and set the power percentage of
Power Good
.
To set one of the items, select the related line with the UP and DOWN keys and then
press and keep pressed ENTER until the command has been accepted. In this way
the Pwr setting will change from On to Off or vice versa and the Mod setting will
change from “x1” to “x10” or vice versa. To change the Power Good percentage
value, after having selected PWG, simply change its value with the UP and DOWN
keys and confirm by pressing ENTER.
In “x10” mode the indication of the instantaneous deviation is multiplied by 10, therefore
the broken line on the preset menu will coincide with 7.5 kHz instead of 75 kHz. This
display mode is useful when you wish to view low deviation levels, e.g. those due to
the pilot tone or the subcarriers.
Power Good is a control and alarm function of the delivered power. When the output
Figure 5.1
Accensione
ESC
ESC
ENTER
Menu Funzione
Menu Potenza
Menu P.A.
Menu Impostazioni
ENTER
ENTER
ENTER
ENTER
Menu di Selezione
ENTER
Menu Versione
Menu Varie
ENTER
Menu Canali