FRONT PANEL DESCRIPTION
(Fig. 1)
1
BAR/DOT
Selector of operation mode (BAR/DOT) for
deviation
meter
2
STEREO/MONO-MPX
Selector for "STEREO" or "MONO-MPX"
operation
3
MODULATION
Modulation meter by "Led Diode Bar"
4
10%-100%
Expansion of modulation meter scale
Pos. 10% - Full scale shows 10%
Pos. 100% -Full scale shows 100%
5
MODE SELECTOR
Pushed button: "STEREO MODE OPERATION"
Pushed button: "MONO MODE OPERATION"
6
L/MPX/R/MONO IN. LEVEL
Continuosly adjustable input level
from -12 to +9 dBm
7
INPUT LEVEL
Input attenuator in five steps
from -9 to +6 dBm
8
DOWN
Control frequency display. A momentary
pushes causes the digit to go down 10KHz
a time
9
ENTER
Enters the frequency on the display into
microprocessor and memory. Once entered,
the frequency is stored until a new
frequency is entered on the front panel
even if the power is turned off for
several days
10
PWR ADJ
A ten turn control which controls the
power output of the exciter.
Once set the power remains at that level
due to AGC action.
11
UP
Controls the display frequency in the
same way as the "DOWN" button, except
that the frequency goes up in 10 KHz
steps
12
FREQUENCY
DISPLAY
Frequency
indicator
13
METER SWITCH
Pushing the switch each time will light
on led at a time in upward direction
14
LEDS
Light indicator indicated which
parameter of the exciter is being
displayed on the analog
meter
15
SWR ALARM
If this indicator lights, it means that
the exciter shut down to a high VSWR
condition on the output
Summary of Contents for PTRL-NV/2/HP/S3
Page 141: ...PTRL NV 2 S3 PTRL NV 2 HP S3 PSSW PTNV 1 6 Appendice Tecnica Rev 0 1 15 05 02...
Page 148: ...PTRL NV 2 S3 PTRL NV 2 HP S3 2 10 CPU NV Technical Appendix Rev 0 1 12 09 02...
Page 151: ...PTRL NV 2 S3 PTRL NV 2 HP S3 CPU NV 5 10 Appendice Tecnica Rev 0 1 12 09 02...
Page 157: ...PTRL NV 2 S3 PTRL NV 2 HP S3 CSSDC30A003 1 6 Technical Appendix Rev 0 1 06 09 02...