5.1 POWER SUPPLY ADJUSTMENT
After changing the power supply module and having reconnected all the
connectors, make the following tests and adjustments:
1)
Disconnect CN1 from the appropriate RF power module.
2)
Connect a suitable dummy load (P>300W on 50Ohm) to the amplifier
output.
3)
Switch the amplifier on.
4)
Check the 50V output of the new power supply using the analog meter
and selecting the appropriate reading with the Meter Selector
switch.
Confirm the reading measuring the output voltage with a digital
multimeter connected to pins 1-2 and 3-4 of the power supply; if
needed adjust the value with P1.
5)
Connect a 50 Ohm P>300W power resistor to the male connector CN1
coming from J2 of the power supply.
Select "I" parameter with the Meter Selector (8 Fig.1) switch; you
should read a current of 10A, if not adjust P3 on the power supply
board for the correct reading.
6)
Be sure that P2 is turned completely counter clockwise.
5.2 R.F. POWER AMPLIFIER MODULE ADJUSTMENT
After you have changed the module perform the following operations.
1)
Connect CN1 (coming from the power supply) to the RF module.
2)
Connect the input connector J1 to PJRL250 R.F. Input Connector and
output connector "J2" to input connector "J1" of low pass filter.
3)
See SETUP 2 (Fig.5), connect a dummy load (P>300W at 50Ohm) to the
R.F. Output connector (5 Fig.2) with a through wattmeter (BIRD 43)
in
series.
4)
Connect an driver able to deliver a power of almost 2W-20W
SETUP 2 / FIG. 5
Summary of Contents for PJRL250
Page 1: ...Manufactured by R V R Elettronica Italy TECHNICAL AND MAINTENANCE MANUAL PJRL250...
Page 17: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 17 FIG 1...
Page 19: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 19 FIG 2...
Page 21: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 21 PHOTO 1 6 5 4 1 2 3...
Page 22: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 22 FIG 3...
Page 39: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 39...
Page 43: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 43...
Page 45: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 45...
Page 47: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 47...
Page 49: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 49...
Page 52: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 52...
Page 55: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 55...
Page 57: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 57...
Page 59: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 59...
Page 61: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 61...
Page 64: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 64...
Page 66: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 66...
Page 68: ...PJRL250 Technical and Maintenance Manual R V R Elettronica S r l Bo Pag 68...