background image

4 / 8

User Manual

Rev. 1.0 - 06/02/09

IBJECT12K10A & IBJECT12K10B

  5.   Installation and configuration procedure

This  section  provides  a  step-by-step  description  of  equipment  installation  and 

configuration  procedure.  Follow  these  procedures  closely  upon  first  power-on 

and each time any change is made to general configuration, such as when a new 

transmission station is added or the injector is replaced.

Once the desired configuration has been set up, no more settings are required 

for normal operation.

The  topics  covered  in  this  section  are  discussed  at  greater  length  in  the  next 

sections, with detailed descriptions of all hardware features and capabilities. Please 

see the relevant sections for additional details.

 

IMPORTANT:

 

When configuring and testing the injector in which the equipment is 

integrated, be sure to have the Final Test Table supplied with the equipment ready 

at hand throughout the whole procedure; the Final Test Table lists all operating 

parameters as set and tested at the factory.

  5.1  Preparation

  5.1.1  Preliminary checks

Unpack the 

IBJECT12K10

 and immediately inspect it for transport damage. Ensure 

that all connectors are in perfect condition.

Provide for the following (applicable to operating tests and putting into service):

√ 

Connection cable kit including:

•  Cables,  with  connector  1+5/8“  (not  included),  between 

IBJECT12K10

  and 

sources of FM analog transmission, and between 

IBJECT12K10

 and output 

in antenna.

•  Cables, with connector 7/16 DIN (not included), between 

IBJECT12K10A

 and 

sources of IBOC digital transmission, and between 

IBJECT12K10A

 and output 

in dummy load. If you are using the 

IBJECT12K10B

 version, use cable with 

connector 7/8 EIA.

The 

IBJECT12K10

 must be installed on a rack that includes an anti-strap device 

to prevent the possibility of accidental disconnection of feeding conductors.

 

Warning:  Disconnect  mains  power  supply  before  beginning  these 

procedure.

Summary of Contents for IBJECT12K10A

Page 1: ...User Manual Manufactured by Italy IBJECT12K10A IBJECT12K10B...

Page 2: ...any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner HD Radio Technolo...

Page 3: ...nstructions 1 2 Warranty 1 3 First Aid 2 3 1 Treatment of electrical shocks 2 3 2 Treatment of electrical Burns 2 4 Unpacking 3 4 1 General Description 3 5 Installation and configuration procedure 4 5...

Page 4: ...IBJECT12K10A IBJECT12K10B ii User Manual Rev 1 0 06 02 09 This page was intentionally left blank...

Page 5: ...equate measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commit...

Page 6: ...is absent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers...

Page 7: ...cription The IBJECT12K10A and IBJECT12K10B henceforth to commonly named IBJECT12K10 manufactured by R V R Elettronica SpA are injectors able to mix a digital signal maximum power 2 5 kW to an existing...

Page 8: ...lied with the equipment ready at hand throughout the whole procedure the Final Test Table lists all operating parameters as set and tested at the factory 5 1 Preparation 5 1 1 Preliminary checks Unpac...

Page 9: ...SMITTING SOURCE ANALOG DIGITAL COMBINER INJECTOR HD RADIO SIGNAL GENERATOR DUMMY LOAD HD RADIO DRIVER AMPLIFIER DJ50 DJ1000 TDX IBOC001 IBJECT12K10 E2X LINK EXPORTER Figure 5 1 High level mixed signal...

Page 10: ...N RF input connector for analog FM source 1 5 8 type 2 REJECTED OUT RF ouput connector of rejected power for dummy load 7 16 DIN type IBJECT12K10A version or 7 8 EIA type IBJECT12K10B version 3 DIGITA...

Page 11: ...gital Weight kg About 7 kg About 7 kg Ambient working temperature C 50 to 70 50 to 70 Whithout condensing Isolation dB At least 38 At least 38 Coupling dB 10 10 Return Loss dB At least 26 At least 26...

Page 12: ...8 User Manual Rev 1 0 06 02 09 IBJECT12K10A IBJECT12K10B This page was intentionally left blank...

Reviews: