HC5
31 / 34
User Manual
Rev. 1.0L - 11/02/02
10. Maintenance Procedures
10.1
Introduction
This section provides general maintenance information and electrical adjustment
for the HC5 hybrid coupler.
Maintenance is divided into categories dependent upon the complexity of the
procedure and the test equipment required to complete the maintenance.
10.2
Safety Consideration
When the amplifier is operational, hazardous voltages and high currents are
accessible internally, and there are high power R.F. signals.
Don’t remove any cover without switching off the system first and close all
covers before restarting the system.
Ensure all primary power is disconnected from the amplifier before attempting
equipment maintenance.
MAINTENANCE LEVEL 1
10.3
Routine Maintenance
The only regular maintenance needed by HC5, is the periodic substitution of the
blowers, and the cleaning of dust filters and any dust accumulated inside the
amplifier.
The time between overhauling of the blowers depends upon several environmental
factors, temperature, humidity, dust pollution etc.
It’s advisable to check the unit every 6 months, and to substitute noisy blowers.
Blowers should be changed as a matter of course at least every 18 months.
10.4
Cards Replacement
10.4.1
CPU Group Replacement
•
Disconnect J1 and J2 alarms card’s connectors.
•
Disconnect JP1 alarms card’s connector.
•
Remove the screws securing the board to the front panel.
•
Carefully extract the card.
Summary of Contents for HC5
Page 1: ...Manufactured by Italy HC5 User Manual LCD version...
Page 4: ...HC5 ii User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Page 6: ...HC5 2 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Page 22: ...HC5 18 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Page 28: ...HC5 24 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...