5.4.3 Power Amplifier (P.A) Menu
This screen is made up of four lines that can be scrolled using the and
buttons and shows the readings relating to final power stage:
Menu 6
Note that these are readings, rather than settings, and cannot be edited (note the
empty arrow).
VPA
Voltage supplied by amplifier module.
IPA
Current draw of amplifier module.
Eff
Efficiency based on ratio of forward power to amplifier module power,
in percent ( FWD PWR/(Vpa x Ipa) % ).
Tmp
Equipment internal temperature reading.
5.4.4 Setup Menu (Set)
This menu lets you view and set operating frequency.
Menu 7
F1
Operating frequency setup. Set a new frequency value and then press the
ENTER
button to confirm your selection; the exciter unlocks from current
frequency (the
LOCK
LED turns off) and will lock to the new operating
frequency (
LOCK
turns back on again).
If you press
ESC
or let the preset time time out, the previous frequency
setting is retained.