5.4.1 Operation Menu (Fnc)
In this menu, you can set
power output
On/Off, toggle between “Local” or “Remote”
control mode and set the
Forward Power Good (PgD)
threshold rate.
To edit an item, highlight the appropriate line using the UP and DOWN buttons and
then press and hold the
ENTER
button (chap. 6.1) until the command is accepted.
This way, Pwr setting is toggled between On and Off and Mod setting is toggled
between “x1” and “x10”. To edit the Power Good rate, simply select item “PgD”
and edit its value using buttons and
; finally, press
ENTER
to confirm (chap.
6.1).
Menu 4
Pwr
Enables (ON) or disables (OFF) amplifier power output.
Loc
Modifies machine operation. In the LOCAL mode, the machine can read
and modify its operating parameters through the navigation keys and the
management firmware, whereas all other sources are locked out. In the
REMOTE mode, the machine can only read its operating parameters;
parameters are modified based on the commands received from other
connected telemetry systems.
PgD
Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power (500W for
PJ500C-LCD
and
1000 W for
PJ1000-LIGHT
), not of forward output power. This means
that this threshold set at 50% will give 250 W and 500 W, respectively,
regardless of set power level. The Power Good feature enables output
power control and reporting. When output power drops below set Power
Good threshold, the equipment changes the state of pin [7] of the DB15
“Remote” connector located on the rear panel (figure 6.2 - [16]).