User Manual
Rev. 1.0 - 30/10/15
PJ1002C-LCD
Menu 6
Note that these are readings, rather than settings, and cannot be edited (note the
empty arrow)..
VPA
Voltage supplied to amplifier module.
IPA
Current absorbed to amplifier module.
Eff
Efficiency based on ratio of forward power to amplifier module power
in percent ( FWD PWR/(Vpa x Ipa) % ).
Tmp
Machine internal temperature..
5.4.4 Alarm Menu (Alm)
This menu shows any alarm conditions occurring during machine operation. Alarm
thresholds are preset at the factory.
Menu 7
FWD
Counter of alarm conditions triggered by forward power.
RFL
Counter of alarm conditions triggered by reflected power.
INP
Counter of alarm conditions triggered by input power.
Reset Alm
Alarm counter reset.
Alarm conditions are numbered from 1 to 10 and reflect the following situations:
forward output power too high, reflected output power too high and input power
too high.
Alarm monitoring cycle is as follows: when an alarm condition is detected, alarm
counter increases by 1 unit, machine goes into lock-out state and the display
shows the cause for the stop. After 15 seconds, the machine attempts to re-start;