16
/ 24
User Manual
Rev. 1.0 - 30/10/15
PJ1002C-LCD
Menu 3
To gain access to a submenu, select menu name (name is highlighted by cursor)
using button or and press the
ENTER
button.
Press
ESC
again to return to the
default menu
(menu 1)..
5.4.1 Operation Menu (Fnc)
5.4.1 Operation Menu (Fnc)
In this menu, you can set
power output
On/Off, toggle between “Local” or “Remote”
control mode and set the
Forward Power Good (PgD)
threshold rate.
To edit an item, highlight the appropriate line using the UP and DOWN buttons and
then press and hold the
ENTER
button until the command is accepted. This way,
Pwr setting is toggled between On and Off and Mod setting is toggled between
“x1” and “x10”. To edit the Power Good rate, simply select item “PgD” and edit its
value using buttons and ; finally, press
ENTER
to confirm.
Menu 4
Pwr
Enables (ON) or disables (OFF) amplifier power output..
Loc
Modifies machine operation. In the LOCAL mode, the machine can read
and modify its operating parameters through the navigation keys and the
management firmware, whereas all other sources are locked out. In the
REMOTE mode, the machine can only read its operating parameters;
parameters are modified based on the commands received from other
connected telemetry systems.
Pg1
Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power (1000W for
P�1��2C��CD
),
not of forward output power. This means that this threshold set at 50%