Make sure fuse or circuit breaker is correct rating for machine. Using fuses or circuit
breakers smaller than recommended will result in ‘nuisance’ shut off from welder inrush
currents even if welding at low amperages.
Failure to follow these instructions can cause immediate failure within the welder and
void machines warranty.
Turn the input power OFF at the mains switch & fuse box before working on this
equipment. Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge
before working inside this equipment. Do not touch electrically live parts
The TIG160FPP Inverter TIG Welder requires a 240V 50/60Hz supply.
It comes with a 3 metre mains cable attached.
Connect wires according to national
coding. Brown wire – Live
Blue wire – Neutral
Green/Yellow Wire – Earth (Ground)
Connecting to a mains electrical supply
THIS MACHINE MUST BE FITTED TO A MINIMUM of 13AMP 240V MAINS
INPUT FOR FULL OUTPUT RANGE TO BE ACHIEVED.
Connecting to an Engine Driven Generator
If connecting this machine to an engine driven generator, please ensure the
following
Minimum Generator KVA Output – 5 KVA continuous
Generator to be fitted with AVR (automatic voltage
regulation) DO NOT USE ON A GENERATOR WITHOUT
AVR
Connecting to a generator without the above minimum requirements will in-
validate your warranty.