20
Maintenance
Routine and periodic maintenance
WARNING!
ELECTRIC
SHOCK CAN KILL
Turn the input power OFF at the mains switch & fuse box before working on this
equipment. Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge
before working inside this equipment.
Do not touch electrically live parts
1. Periodically remove the side/top panels of machine and clean out machine with a
low-pressure dry air line paying particular attention to PC Boards, Fan blades,
HF points
2. Inspect input and output cables & hoses for fraying, cuts & bare spots
3. Keep TIG torch and cables in good condition
4. Clean air vents to ensure proper air flow and cooling
5. The fan motor has sealed bearings which requires no maintenance
Troubleshooting
Service & repair should only be performed by R-Tech welding trained personnel. Unauthorised
repairs performed on this welding equipment may result in danger or injury to the technician and
machine operator and will invalidate your warranty.
For your safety and to avoid electric shock, please observe all safety notes and
precautions detailed throughout this manual
The troubleshooting guide is provided to help you locate possible machine
malfunctions If the fault / problem is not listed below check our support page on our
website
www.r-techwelding.co.uk/support
or contact R-Tech by phone
.
Contact details can be found on front of this manual and our website