1. Field of application and conditions for use
The powered respirator is used for dust and particles removal only, not for gases or vapors
and is used to reduce or remove resistance to inhalation during respiration by producing a
constant airflow. The unit is designed with manufacturer’s minimum design flow rate 170 litres
per minute (the flow rate at which the equipment still will fulfill the requirements of the class in
EN12941:1998 + A1:2003 + A2:2008). The actual working time will be about 8 hours.
2. Description
A complete powered respirator apparatus consists of :
filter (chart 1), supplied with a belt and a comfort plate
◆
Blower master unit, provided with a dust TH3
filter, a steel pre-filter and an activated carbon
.
◆
Rechargeable battery, which is equipped underside the apparatus.
◆
A hose with a bayonet connector to blower unit and a bayonet connector to mask,
◆
Battery charger, fully automatic.
Spare parts list:
The unit supplies an overcapacity of clean and filtered ambient air, which is fed to mask. It
allows the user to breathe in air without himself having to overcome the resistance of the filter.
Considering that an adult person requires some 50 litres of air per minute, the overcapacity
1
.
TH3
filter
(RT
-
P
A
PR
-
10)
2
.
P
re-filter
(
stainless
S
teel wire mesh
)
(
RT
-
P
A
PR
-
20
)
3
.Activated carbon filter
(RT
-
P
A
PR
-
30)
4.
S
tandard rechargeable battery
(RT
-
P
A
PR
-
50)
***
O
ption
:
H
igh capacity rechargeable battery
(RT
-
P
A
PR
-
55)
ensures an overpressure and thus a high degree of protection.
Chart 1
With a fully charged battery the unit will operate for about 8 hours. The unit contains a warning
facility to warn the user against reduced air supply, due to clogged filter or low battery.
3.Use