- 20 -
XR-OP-EN
OPEN RECOVERY LID:
1. Release both latches
(A)
on Recovery
Tank lid
(SEE BELOW)
.
2. Rotate lid fully open.
FLUSH RECOVERY TANK:
1. Rinse the Recovery Tank after every use. This will
prevent heavy build-up on the bottom of the tank,
foul odors as well as clogging of the Drain Hose.
2. Remove Drain Hose
(C)
and open to allow for
drainage of the Recovery Tank
(SEE BELOW)
.
3. Flush Recovery Tank with water hose.
4. After rinsing, reattach the Drain Hose
(C)
on stopper
(SEE ABOVE)
.
NOTICE
Keep water off of Control Panel.
CLEAN “DRAIN SAVER”:
With Recovery Lid open and Tank fully drained:
1. Remove 2'' Squeegee Intake Hose
(D)
from
“Drain Saver” strainer
(E)
(SEE BELOW)
.
2. Remove stainless screen and dispose of debris.
3. Rinse screen with fresh water from the
outside while holding the screen upside
down. This will allow for better cleaning.
4. Replace the screen into the bracket.
5. Replace 2'' Squeegee Intake Hose.
CLEAN VACUUM SCREEN:
With Recovery Lid open and Tank fully drained:
1. Remove Vacuum Screen retaining
clip
(F)
(SEE BELOW)
.
2. Pull Vacuum Screen and fl oat ball
assembly
(G)
off of the Vacuum Box.
3. Rinse with hot water.
4. Dry
thoroughly.
5. Replace the Vacuum Screen onto box.
6. Replace and tighten retaining clip.
C
D
E
F
G
A