Page 4

05305L-90(J)

EMC COMPLIANCE

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation 

is subject to the following two conditions: (1) this device may not 

cause  harmful  interference,  and  (2)  this  device  must  accept  any 

interference  received,  including  interference  that  may  cause 

undesired operation.
This  equipment  has  been  tested  and  found  to  comply  with  the 

limits for a Class A digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection 

against harmful interference when the equipment is operated in a 

commercial  environment.  This  equipment  generates,  uses,  and 

can radiate radio frequency energy and, if not installed and used 

in  accordance  with  the  instruction  manual,  may  cause  harmful 

interference to radio communications.  Operation of this equipment 

in a residential area is likely to cause harmful interference in which 

case the user will be required to correct the interference at his own 

expense.
This ISM device complies with Canadian ICES-001.

Cet appareil ISM est conforme à Ia norme NMB-001 du Canada.

EN55011/CISPR 11, Group 1, Class B device.
Class B equipment is suitable for use in domestic establishments 

and  in  establishments  directly  connected  to  a  low  voltage  power 

supply  network  which  supplies  buildings  used  for  domestic 

purposes.
Note:

Wind  Monitor  sensors  with  Line  Driver  Output  may  be  disrupted 

by  radiated  RF  interference  at  240-300  MHz.    To  meet  EMC 

Compliance,  (2)  YOUNG  18500  ferrite  chokes  must  be  installed 

on  the  cable,  one  near  the  sensor,  and  one  near  the  recording 

instrument.    (Each  choke  must  have  the  cable  pass  through  the 

center hole at least 2 times, creating 1 loop around the outside as 

shown below.)

WARRANTY

This  product  is  warranted  to  be  free  of  defects  in  materials  and 

construction for a period of 12 months from date of initial purchase. 

Liability is limited to repair or replacement of defective item. A copy 

of the warranty policy may be obtained from R. M. Young Company.

CE COMPLIANCE

This  product  has  been  tested  and  complies  with  European  

CE requirements for the EMC Directive.  Please note that shielded 

cable must be used.

Summary of Contents for 05305L

Page 1: ...MENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com P N 05305L 90 REV J111215 WIND MONITOR AQ WITH 4 20mA...

Page 2: ...ns As a general rule the air flow around a structure is disturbed to twice the height of the structure upwind six times the height downwind and up to twice the height of the structure above ground For...

Page 3: ...ated in comparison with a wind speed standard Contact the factory or your supplier to schedule a NIST National Institute of Standards Technology traceable wind tunnel calibration in our facility To ca...

Page 4: ...n through front of main housing and turn potentiometer adjust thumbwheel until signal conditioning system indicates proper value d Tighten set screw on potentiometer coupling 8 REPLACE NOSE CONE a Scr...

Page 5: ...se This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme Ia norme NMB 001 du Canada EN55011 CISPR 11 Group 1 Class B device Class B equipment is suitable for use in domestic es...

Page 6: ...TION FORMULAS Model 05305L WIND SPEED vs mA OUTPUT m s 6 250 x mA 25 knots 12 125 x mA 48 6 mph 13 980 x mA 56 km h 22 500 x mA 90 WIND DIRECTION vs mA OUTPUT DEGREES 22 5 x mA 90 CABLE WIRING DIAGRAM...

Page 7: ...Page 6 05305L 90 J BEARING REPLACEMENT POTENTIOMETER ADJUSTMENT...

Page 8: ...G 05330D TRANSDUCER ASSEMBLY 05324 2 VERTICAL SHAFT BEARING 05187 PROPELLER NUT 1 4 20 05164C PROPELLER SHAFT W HUB 6 32 x 1 8 SET SCREW 5 05127 MAIN HOUSING LATCH 6 32 x 3 8 FLAT HD SCREW 05126C VERT...

Page 9: ......

Page 10: ...Accessories Model 18802 Anemometer Drive Model18112 Vane Angle BenchStand Model 18310 Propeller Torque Disc Model18331Vane Torque Gauge Model 18301 Vane Alignment Rod Model 18212 Vane Angle Fixture T...

Page 11: ...ne Torque Gauge checks vane bearing torque of the Wind Monitor family sensors Slip the fixture over the main housing and make simple yet accurate vane torque measurements Charts relating vane torqueto...