www.rm-suttner.com
page 3, Ver. 01.2021
10
Check valve
(optional) to protect
the compressed-air
system
4
Disinfectant
Suction height
max. 3 m
9
Shut-off
valve open
8
Pressure
reducer
5
Injector
2
Foam gun
ST-2725, ST-3100, ST-3300, ST-3225
1
Foam lance
ST-20: 310 060 5,
ST-20: 310 061 0,
ST-20: 310 063 0, 502 808
6
Pump
Pressure min. 5 bar.
Pressure max. 350 bar.
Flow min. 8 l/min. /
max. 30 l/min
11
Suction
hose
3
High-pressure hose
recommended nominal
width 12 mm
Length max. 20 m
7
Air com-
pressor
max. 3 m
Length max. 5 m
User Manual easy
ST-160.2 foam and disinfectant unit. Product No.: 200 160 635
4
Disinfectant
Suction height
max. 3 m
1
Foamlance:
ST-72, ST-74, ST-75
3
High-pressure hose.
Nominal width min. 8.
Length 20 m.
Recommended nominal
width 10. Length 20 m.
2
Spray gun:
ST-1500, ST-2300, ST-2700, ST-2320,
ST-2315,ST-2615, ST-2620
6
Pump
Pressure min.
80 bar.
Flow min. 8 l/min.
5
Injector
7
Suction
hose
max. 3 m
length max. 5 m
a) passive foamlance
Typical types of connection:
The air for foam generation is generated by the compressed-air generator (
7
)
b) active foam lance
The air for foam generation is
sucked in by the lance (
1
)
Setup:
Lance with air injector:
Use the injector in the indicated pressure, volume flow, and temperature range, only. Before starting work, check the
values at the high-pressure generator and adjust them if required.
Foam quantity and concentration can be set using dosing inserts.
After studying the safety rules the use of the injector is very simple.
In order to clean the outside, use a lint-free cloth and do not use any aggressive cleaning agents.
Rinse the suction hoses using clear water to rinse the check valve.
After usage and prior to longer interruption of work (more than 1 hour), rinse the injector using clear water.
Operation
Cleaning