11
BA_BM_HS-300-LARGE_EN_45-21.docx
4.7
Hazardous Areas
Source
Area
Cause
Risk
Prevention
Foot pump
HS 300 LARGE | FH
only:
On the foot
pedal for height
adjustment
Slipping off the
foot pedal
Injuries to feet
and legs
Keep foot pedal
and shoes dry
Wear work shoes
with non-slip soles
Mechanics
Lifting scissor /
Subframe
Crushing and
shearing points
Loss of limbs,
crushing of
hands, increased
risk of injury and
even death
Do not reach under the
tabletop or into the scis-
sors during operation and
do not move your body
into this area
Before maintenance work,
always lock the safety
catch to secure the plat-
form first (section
Hydraulic
system
On hydraulic
cylinders and all
oil-bearing parts,
seals and lines
Oil spraying
out with high
pressure in
case of damaged
cylinder or seals
Injuries and
poisoning of
the eyes
Wear safety goggles
or face shield
Repair damaged parts
and/or seals immedi-
ately (only qualified
personnel!)
Electrics
HS 300 LARGE | AH
only:
At the mains
connection and the
supply line of the
battery charger as
well as at the pole
terminals of the 12
V battery
Electrical voltage
(230 VAC) at the
battery charger
as well as high
currents at the
battery pole ter-
minals and fur-
ther cables
Electric shocks
with increased
risk of injury
up to death
Avoid moisture
Have defective parts / insu-
lation repaired immedi-
ately (only qualified per-
sonnel!)
Do not touch energised
components
Switch off the main switch
during all maintenance and
repair work
Pneumatics
HS 300 LARGE |
VAKUUM only:
Rear openings of
the Vacuum pump
Outflowing air,
gases and dust
Injuries
of the eyes
Do not look into the
openings, wear safety gog-
gles or face shield