STEP 6:
a. The lanyard is provided as a means to support the
fixture from the junction box while connecting the
electrical wires. This enables the fixture to hang from
the junction box and your hands are free to make the
wire connections.
b. Turn the button stop so it may be inserted into the
crossbar slot. Make sure the button stop is completely
inside the crossbar.
c. Slowly release the fixture to make sure it is supported
by the button stop.
Crossbar Assembly
Button Stop
Lanyard
Slot
Fixture Loop
STEP 5:
a. Connect the fixture loops to the chain links on the
underside of the ceiling canopy by using quick links.
Quick Link
Chian Links
4
2016 QuoizelInc.
STEP 7:
a. Confirm that the mounting height is acceptable. Refer to STEP 3 if
changes are required.
: To make the next step easier, cut the supply wire and
ground wire 24 inches longer than the distance from the fixture
loop to the ceiling.
: Please pay attention to the polarity (wires labels L &
N) when cutting wires. Wire identification will be needed in STEP
8.
b. Pass supply wires and ground wire through the quick link and the
ceiling canopy and remove any remaining slack in the wire.
c. Trim excess fixture wire leaving a minimum of 6 inches extending
beyond the edge of the ceiling canopy.
d. Separate the smooth side and ribbed side of the supply wire to
about 3 inches from the end.
e. Using wire strippers, strip each wire ½ inch from the end.
Note
Important
Supply Wires
and Ground Wire
STEP 8:
* Use Wire Connectors (supplied) to connect the wires.
ground wire
green ground screw
ground screw
ground wire
supply ground
house white wire
fixture supply
wire (ribbed sided)
house black (or red) wire
fixture
supply wire (smooth side)
outlet box
a) Ground Wire:
1. Wrap supply
around
on mounting bracket, no less than 2 in. from the end of
the wire. Tighten
.
2. Connect fixture green
to
wire with wire connector.
b) Supply Wire:
1. Connect the
to the
from fixture identified with the label
“N”.
2. Connect the
to the
from fixture identified with
the label “L”.
3. Wrap each connection with approved electrical tape
and carefully stuff all of the connected wires into the
.
WHITE OR RIBBED
BLACK (OR RED) WIRE
FROM HOUSE
FROM HOUSE
RIBBED SIDE OF WIRE
FIXTURE
FROM
IDENTIFIED
SMOOTH SIDE OF WIRE FROM
FIXTURE IDENTIFIED
WITH THE LABEL “N”
WITH THE LABEL “L”
GROUND WIRE
GROUND WIRE
FROM SUPPLY
FROM FIXTURE
GREEN GROUND SCREW
GROUND WIRE
GROUND WIRE
FROM SUPPLY
FROM FIXTURE
OR