Section VIII – Maintenance
94 Quincy Vacuum Pump-QSV Series
CAUTION!
The vessel cover is supported by two gas springs, from which one is executed with a locking tube.
To close the cover, press the locking tube as instructed on the gas spring. Always support the
cover by hand while manipulating it to avoid unwanted closure
.
Close the cover of all separator tank. Caution not to squeeze the O-ring.
Tighten bolts.
7.8 Pressure switch
Testing
CAUTION!
The pressure switch test can only be performed by authorized personnel and is protected by a
security code. Refer to Airlogic Graphic controller.
If the pressure switch does not open at the set pressure of 1500mbar (a), it needs to be replaced.
WARNING!
No adjustments are allowed. Never run the vacuum pump without pressure switch
.
7.9 Service kits
Service kits
For overhauling and for preventive maintenance, a wide range of service kits is available. Service kits
comprise all parts required for servicing the component and offer the benefits of genuine Quincy parts while
keeping the maintenance budget low.
Also a full range of extensively tested lubricants, suitable for your specific needs is available to keep the
vacuum pump in excellent condition.
Consult the Spare Parts List for part numbers.
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...