Page 6 

 

 

 

animals. Get medical help in case a battery 
has been swallowed. 

 

When replacement batteries are required, 
replace all four batteries inside the device 
battery compartment with suitable new ones. 

 

Do not store batteries in environments with 
loose metal parts or exposed to moisture, 
heat, fire or direct sunlight. 

 

Do no expose batteries to vibration, impacts or 
deformation. 

 

Fire, explosion and sever burn hazard. Do not 
recharge, crush, disassemble, heat above 
100

°

C, incinerate batteries or expose contents 

to water. 

 

Consult IATI guidelines describing safe air 
transport of Li-ion batteries. 

 

Dispose of batteries according to local 
regulations. A recycle program might be 
applicable. 

 

Section 2: General description 

 

EQ LTE™… Compressed air analytics made 
easy! 

 

Advanced hardware, software and cloud 
computing solutions that enable compressed 
air and vacuum systems to be quickly and 
easily audited. 

 

EQ LTE™ offers market-leading, innovative 
and technically advanced solutions that 
streamline traditional compressed air system 
audits. 

 

Seamlessly integrating robust hardware and 
software platforms… The success of EQ 
LTE™ has been built upon a unique ability to 
seamlessly integrate our own robust processor 
and input/output hardware platforms with a 
comprehensive software library to provide a 
bespoke compressed air and vacuum auditing 
solution. 

 

Streamlining data collection, improving 
analysis… First, our EQ LTE™ data loggers 
incorporate high quality sensors to collect and 
store information relating to a system’s 
pressure, temperature, moisture dew point and 
flow rate. In addition, our current and voltage 
loggers enable true power to be accurately 
calculated. 

 

                                                            

The very latest Bluetooth technology then 
enables this information to be effortlessly 
transferred from multiple data loggers to a 
single, intelligent EQ LTE™ base station. In 
turn, the base station transfers this data to our 
quincy.scadar.net cloud computing platform. 
Here, it is encrypted and stored so that is can 
be securely accessed and interrogated by 
users 24 hours a day. 

 

Combining unique application expertise with 
proven hardware and software platforms to 
deliver the complete, value-adding analytics 
service… EQ LTE™ provides customers with 
the reassurance of working with an 
experienced, market-leading partner 
positioned at the very forefront of technology. 

 

Evaluating requirements… Whilst developing 
EQ LTE™, we took time to carefully evaluate 
traditional compressed air auditing 
procedures. Once these were clearly 
understood, our analytics specialists began to 
formulate a solution that made things simpler. 

 

PLC hardware engineering… Our partners 
are vastly experienced in the development of 
processor and input/output hardware 
platforms. This expertise has enabled us to 
manufacture a range of EQ LTE™ data 
loggers that feature 16 bit precision sensor 
inputs with the capacity to store more than 1.4 
million data samples. 
Powered by 110-240v AC mains or batteries 
that can offer an incredible working life of two 
years or more, our data loggers record 
information on pressures up to 60 bar (870 
psi), temperatures from -50°C - +200°C 
(-58°F - +392°F), moisture dew point from - 
80°C - +20°C (-112°F to +68°F), flow rates to 
185m/sec (607 ft/sec) and current and voltage 
from 10 – 800Amp and 100 V – 700V 
respectively. Additionally, there’s a 4-20mA 
data logger that can be used with a variety of 
sensor types. 

 

EQ LTE™ base stations are also robustly 
constructed and incorporate a 3.5” VGA color 
display and ergonomically designed keypad. 
PLC software development 

Summary of Contents for EQ LTE 2014900356

Page 1: ...Equipment Technical Manual Base Station...

Page 2: ...wer Supply 100 240vAC input DC output power supply c w plug assortment Note No case is supplied with this kit items are supplied loose EQ LTE Logger Pressure 0 16BAR complete case kit 2014900357 20149...

Page 3: ...t Logger assembly EQ LTE Sensor moisture dewpoint EQ LTE Sensor moisture dewpoint mounting chamber EQ LTE Power Supply 100 240vAC input DC output power supply c w plug assortment EQ LTE Logger 4 20mA...

Page 4: ...st use 4 2 4 General operation 4 2 5 Power supply 4 2 6 Logger battery compartment 4 2 7 Keypad 4 2 7 1 Bluetooth key and LED 4 2 7 2 Diagnostic key and LED 4 2 8 Data logger installation 4 2 9 EQ LTE...

Page 5: ...hat an organization or website is referred to in this work as a citation and or a potential source of further information does not mean that the author or the publisher endorses the information the or...

Page 6: ...he licensed materials including the specific design and structure of individual programs constitute trade secrets and or copyrighted material of Quincy Compressor Customer agrees not to disclose provi...

Page 7: ...the device personnel must use relevant safe working practice and observe all relevant local health and safety requirements and regulations Lethal voltages may be present at or around the device Elect...

Page 8: ...the ratings supply voltage frequency pressure temperature altitude humidity and environmental rating for which it is designed Do not operate the device without battery door enclosure open or covers r...

Page 9: ...ated The very latest Bluetooth technology then enables this information to be effortlessly transferred from multiple data loggers to a single intelligent EQ LTE base station In turn the base station t...

Page 10: ...g device ID serial number and original equipment manufacturer bar code data is located on the back elevation of the base station 4 1 2 Preparing for first use Each EQ LTE base station is supplied with...

Page 11: ...onment and EQ LTE data loggers Once EQ LTE data loggers return from the audit location simply synchronize with the EQ LTE base station once more and transfer your logged data from the EQ LTE base stat...

Page 12: ...Wizard configuration files from base station to logger s using Bluetooth Base to logger s Distributing logger configuration files to loggers Logger s to base Used to transfer data files from logger s...

Page 13: ...t locks either side of carry handle Transportation feet for stability when stacked Formed cushion insert Tamper resistant label providing device ID serial number and original equipment manufacturer ba...

Page 14: ...data loggers also feature an external power supply input This is used to power the data logger sensor Note The use of an external power supply unit does not eliminate the use of or need for the data...

Page 15: ...Slow flash Not configured Troubleshooting Create audit configuration transfer from cloud to base station and then from base station to logger Fast flash Configured not sensing data Troubleshooting Ch...

Page 16: ...ing temp 0 C 55 C 32 F 131 F Power batteries Four AA lithium primary cells Li SOCI2 3 6V 2700mAh Real time clock Precision real time clock temp compensated crystal Maximum deviation 0 4s day Sample ca...

Page 17: ...wet environments Do not use the device if it operates incorrectly Protection can be compromised Examine the test leads for damaged insulation or exposed metal Check test lead continuity Replace damage...

Page 18: ...deviation 0 4s day Sample capacity More than 1 4 million samples 16 days continuous logging Sample frequency 1 second fixed resolution 4 2 10 2 Sensor installation Warning risk high pressure Isolate...

Page 19: ...and should be chosen according to practical constraints Observe and maintain safe working practices at all times Identification EQ LTE Logger temperature 2014900365 EQ LTE EQ LTE Temperature data log...

Page 20: ...point data logger Precision data logging Definition Function Logger A D resolution 16 bits Bluetooth slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due t...

Page 21: ...ets at the sensor element Condensation or water on the sensor element may cause a fault and may corrupt sensor data The size of the inlet and outlet pipe diameter sections must not be less than the sp...

Page 22: ...present in area L of the diagram below Be aware that the air flow sensor is directional L Length of pipe section At inlet L1 15 x inner pipediameter At outlet L2 5 x inner pipe diameter D Inner diamet...

Page 23: ...39 69 Oxygen O2 176 4 578 74 Nitrous oxide N2O 181 4 595 14 Natural gas NG 109 4 358 92 DIN 1343 0 C 1013 25mbar Maintenance The sensor head should be checked regularly for dirt and cleaned if necessa...

Page 24: ...slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due to propagation conditions material coverage production sample variations antenna configurations and b...