Appendix B - Technical Data
82
Quincy Compressor-QSI
®
QSI 1000
¯
¯
¯
¯
¯
S
TANDARD
°
°
°
°
°
Full Load Operating Pressure
psig
100
110
125
Maximum Operating Pressure
psig
115
125
140
Minimum Operating Pressure
psig
Æ
75
Å
Maximum Ambient Operating Temperature:
Less Cabinet
°F
Æ
115
Å
With Cabinet
°F
Æ
110
Å
Minimum Ambient Operating Temperature
°F
Æ
32
Å
Compressor Drive Motor
HP
Æ
200
250
Rotor Diameter
mm
Æ
321
Å
Male Rotor Speed
rpm
Æ
1785
1790
Female Rotor Speed
rpm
Æ
1190
1193
Rotor Tip Speed
m/sec.
Æ
30.03
30.11
Inlet Capacity
acfm
1014
1010
1003
Displacement at Operating Speed
cfm
Æ
1120
1123
Volumetric Efficiency
%
90.5
90.2
89.3
Aftercooling
Heat Rejection:
Fluid Cooler
BTU/min.
7609
7730
8310
Aftercooler
BTU/min.
1530
1610
1731
Aftercooler Approach (standard conditions)
°F
Æ
3-5
Å
Maximum Allowable Static Backpressure
in./H
2
O
Æ
0.125
Å
Fan Motor
HP
Æ
5
Å
Fan Motor
rpm
Æ
1180
Å
Fan Flow
cfm
Æ
19300
Å
Water-cooled Cooling
Recommended Inlet Water Pressure
psig
Æ
40-100
Å
Vent Fan Motor
HP
Æ
1/2
Å
Aftercooler Approach to Cooling:
Water Temperature
°F
Æ
13-18
Å
Water Flow less Aftercooler at: 50°F
gpm
Æ
10.6
13.2
70°F
gpm
Æ
14.8
19.6
90°F
gpm
Æ
25.6
42
Water Flow with Aftercooler at: 50°F
gpm
Æ
14.1
17.4
70°F
gpm
Æ
19.1
25.5
90°F
gpm
Æ
32.4
53
Compressor Fluid
Total Fluid Capacity
gallons
Æ
46
Å
Reservoir Fluid Capacity
gallons
Æ
37.25
Å
Fluid Flow
gpm
Æ
59.5
Å
Typical Fluid Carryover
ppm
Æ
1.5-5
Å
Normal Airend Discharge Temperature
°F
Æ
175-195
Å
Sound (at 1 meter)
Unenclosed (AC/WC)
dB(A)
Æ
89/86
Å
Standard Cabinet (AC/WC)
dB(A)
Æ
85/79
Å
Low Sound Cabinet (AC)
dB(A)
Æ
82
Å
Summary of Contents for QSI 1000
Page 2: ......
Page 7: ...This page intentionally left blank ...
Page 11: ...Section I General Quincy Compressor QSI 5 MODEL IDENTIFICATION ...
Page 25: ...Quincy Compressor QSI 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...Quincy Compressor QSI 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...Appendix A Dimensional Drawings 60 Quincy Compressor QSI QSI 220 245 air cooled ...
Page 67: ...Appendix A Dimensional Drawings Quincy Compressor QSI 61 QSI 220 245 water cooled ...
Page 68: ...Appendix A Dimensional Drawings 62 Quincy Compressor QSI QSI 250 300 air cooled ...
Page 69: ...Appendix A Dimensional Drawings Quincy Compressor QSI 63 QSI 250 300 water cooled ...
Page 70: ...Appendix A Dimensional Drawings 64 Quincy Compressor QSI QSI 335 370 air cooled ...
Page 71: ...Appendix A Dimensional Drawings Quincy Compressor QSI 65 QSI 335 370 water cooled ...
Page 72: ...Appendix A Dimensional Drawings 66 Quincy Compressor QSI QSI 440 500 air cooled ...
Page 73: ...Appendix A Dimensional Drawings Quincy Compressor QSI 67 QSI 440 500 water cooled ...
Page 74: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSI QSI 540 600 air cooled ...
Page 75: ...Appendix A Dimensional Drawings Quincy Compressor QSI 69 QSI 540 600 water cooled ...
Page 76: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSI QSI 675 750 air cooled ...
Page 77: ...Appendix A Dimensional Drawings Quincy Compressor QSI 71 QSI 675 750 water cooled ...
Page 78: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSI QSI 925 1000 air cooled ...
Page 79: ...Appendix A Dimensional Drawings Quincy Compressor QSI 73 QSI 925 1000 water cooled ...
Page 80: ...Appendix A Dimensional Drawings 74 Quincy Compressor QSI QSI 1175 1250 1400 1500 air cooled ...
Page 81: ...Appendix A Dimensional Drawings Quincy Compressor QSI 75 QSI 1175 1250 1400 1500 water cooled ...
Page 99: ......