Section Iv - QCS00 & QCS1600
Putting into Operation
QCS00/1600 Filter Set(s):
Each QCS oil/water
separator supplied by the
manufacturer is equipped
with a filter set.
Check the correct seating
of the filters before putting
the unit into service:
Open the container lid.
The handles of the
main filter must be
locked into place on the inner wall.
When closing the housing lid, fit the
prefilter onto the guide pipe.
Fill the QCS with clean water:
Fill water into the pre-separator.
Fill water into the main container.
Shut off the water when it starts to
come out at the water outlet.
notiCe
The water level will drop due to the
gradual water intake of the filter.
Add clean water as required and
reinstall the lid.
♦
♦
♦
♦
♦
♦
♦
The QCS unit is now ready for operation:
Compressor condensate can now flow into
the QCS via the pressure relief chamber.
notiCe
Open the outlet of the condensate
drain and check all connections for
leaks.
The service valve must be closed during
operation.
22
Quincy Compressor-QCS High Efficiency Emulsion Separators