5
Technical data
5.1
Reference conditions
Air inlet pressure
7 bar(e)
102 psig
Air inlet temperature
20˚C
68 ˚F
Ambient temperature
20˚C
68 ˚F
5.2
Principal data
Maximum compressed air inlet pressure
Coalescing filters
(P-G-C) + WS: 16
bar(e)
Coalescing filters
(P-G-C) + WS:
232 psig
Minimum compressed air inlet pressure
1 bar(e)
15 psig
Minimum compressed air inlet temperature
1˚C
34˚F
Maximum compressed air inlet temperature for V filters
50˚C
122˚F
Maximum compressed air inlet temperature coalescing filters and
WS
80˚C
176˚F
Maximum compressed air inlet temperature particulate filters
120˚C
248˚F
Minimum ambient temperature
-20˚C
-4 ˚F
Maximum ambient temperature for V filters
50˚C
122˚F
Maximum ambient temperature for other types
50˚C
122˚F
5.3
Specific data
Performance data at nominal volume flow and at reference conditions, unless otherwise stated.
P filter
P
Challenge/inlet oil concentration
mg/m
3
10
Initial pressure drop over filter when dry
mbar
50
Initial pressure drop over filter when saturated
mbar
80
Oil carry-over (aerosol)
mg/m
3
<1
Total mass efficiency
%
90
Count efficiency
MPPS
92.03 %
1 µm
95.29 %
0.01 µm 95.65 %
ISO 8573-1 2010 Class
3:-:3