Climate Control Series
Quincy Compressor
2022209100, August 2018
9
the premises where the original delivery was made. Retain all containers and
packing for inspection by the carrier.
A claim form can be requested from the carrier: Standard Form for Pre-
sentation of Loss and Damage Claims (form # 3208). Your claim will need to
be substantiated with the following documents:
a.) form #3208
b.) original bill of lading
c.) original paid freight bill
d.) original invoice or certified copy
e.) other particulars obtainable in proof of loss or damage (photos,
damage inspection, etc.)
The proper description and classification of our product in the National
Motor Freight Classification 100-H, contained in item 118100, reads as follows:
“Compressors, air, or air ends: with or without air tanks, hose or nozzles,
mounted or not mounted.”
We suggest that these instructions be circulated to your shipping and
receiving personnel.
•Location
Quincy air compressors must be installed and operated in a secure and
upright position in an area that is clean, dry, well lighted, adequately venti-
lated, and protected from adverse conditions and/or elements. Inspection and
mainte nance checks are required daily. Therefore, sufficient space needs to
be provided around the compressor for safe and proper in spection, cleaning,
and maintenance.
The compressor must not be installed closer than 24 inches to a wall or
another compressor. This allows ample circu la tion of air across the compres-
sor cylinders, heads and cooler (if so equipped). Do not allow hot air from ad-
ditional equipment blow towards the compressor. If at all possible, the pulley
drive system (i.e. motor pul ley, compressor sheave, belts and guard) should
be located next to a wall to minimize any danger created by the drive system
while the compressor is operating.
Quincy compressors should be operated in temperatures under 104°F. In
cold cli mates, the compressor should be installed in a heated building.
Do not operate this compressor in ambient temperatures lower
than -15° F. A crankcase heater is recommended for a compressor
that is to operate in temperatures under 32° F.
Under no circumstances should a compressor be used in an area
that may be exposed to toxic, volatile, or corrosive atmo sphere. Do
not store toxic, volatile, or corrosive agents near the compressor.
CAUTION !
WARNING !