Setting opening times values 

A different opening time value can be set to opening via the keyboard and via the optional 
bypass pushbutton. 
The times values are from 1 second till 9 seconds. 
Enter the programming code: if not changed is: 123456 *, the green led will blink. 
now the following sequence should be entered: memory cell number 00, opening time via 
keyboard (1 digit) followed by opening time via bypass pushbutton (1 digit). for verification 
repeat the same sequence of memory cell number 00 opening times values. Confirm with 

*

To finish press: 

#

Remark: when setting the keyboard opening time, a value to the bypass pushbutton must be 
set also, even if not installed. 

 

Summery and examples 

Programming option 

execution 

default 

Entering programming code 

 123456  * 

 

Changing programming code 
For example: new code 
777456 

Enter programming code * 

 99-777456  99-777456  * 

123456 

Storing a new access code 
For example: cell number 01 
access code: 2040 

Enter programming code * 

 01-2040 01-2040   * # 

All the cells are empty  
(not 0) 

Canceling access code stored 
in cell number 37 

Enter programming code * 

 37-# # 37-# #   * # 

 

Setting opening time from 
keyboard to 2 seconds and 
from bypass pushbutton to 5 
seconds 

Enter programming code * 

 00-25 00-25   * # 

3 seconds from keyboard, 
3 seconds from bypass 
pushbutton 

 

 
 

operation 

 

Opening the lock using the keyboard 

Enter the access code confirm with 

*

The lock will be open for the time value it was programmed. 
Each key stroke is followed by a Beep sound, entering a false code or invalid typing is 
followed by a “Beep-Beep-Beep” sound sequence 
 
When exit the secured room press the bypass pushbutton, the lock will be open for the 
programmed time value (could be set to different value than entering). 

Summary of Contents for QK-KEY

Page 1: ...Via Seccalegno 19 36040 Sossano Vicenza Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quiko biz Installation Guide QK KEY Surface Mount ...

Page 2: ...t Normally close for magnetic lock Jumper on 2 left pins After installing the lock in the door frame Route the following wires to the encoder 1 2 wires from power supply 2 2 wires to the lock 3 2 wires from optional bypass pushbutton Using a Phillips screwdriver open the plastic top cover screws carefully pull up the panel Expose the 4 covered insulations bores and the round wires bore Attach the ...

Page 3: ...ry cell number 2 digits access code 2 6 digits and for verification again the same memory cell number the same access code Confirm with To finish press You can add more access codes in cells 01 98 in the same way to use the access code press the access code followed by Changing the programming code Enter the programming code if not changed is 123456 confirm with the green led will blink now the fo...

Page 4: ...ng programming code 123456 Changing programming code For example new code 777456 Enter programming code 99 777456 99 777456 123456 Storing a new access code For example cell number 01 access code 2040 Enter programming code 01 2040 01 2040 All the cells are empty not 0 Canceling access code stored in cell number 37 Enter programming code 37 37 Setting opening time from keyboard to 2 seconds and fr...

Page 5: ...QK KEY Installation Guide 5 Electrical Drawing REX LINE 12VAC Relay RLY DEFAULT 12V AC Bypass pushbutton Electric lock RLY Normally open Jumper as in drawing ...

Reviews: