56
Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Procedure
Steps
1.Remove panel
2.Remove filter
3.Remove horizontal louver and front case
panel
filter
front case
horizontal louver
electric box cover 2
Open the front panel.Push the rotor shaft
on both sides of the panel to make it
separate from the groove .Remove the
panel.
Remove axial sleeve of horizontal louver.
Loosen the clasp of the filter.Push the
filter inward and then draw it upward to
remove it.
Bend the louver outwards and then
remove the louver.
Loosen the screws of the electric box
cover2 with screwdriver.Remove the
electric box cover2.
Open the screw cap on the front case.
Loosen the six clasps of the front case.
Remove the front case.