background image

13

1-888-QUIETCOOL

10 YEAR LIMITED WARRANTY 

WHOLE HOUSE FANS LIMITED WARRANTY 

 QC ES LINE (Energy Saver) WHOLE HOUSE FANS 

QC Manufacturing Inc. extends this warranty to the original purchaser of the following QuietCool Classic 

Line Models ----QC ES-1500, QC ES-2250, QC ES-3100, QC ES-4700 and QC ES-6400 ---- installed 

and used in a residence under normal conditions within the United States: 

A.

Ten year coverage applies to the QuietCool motor fan assembly. At our option we will repair 

      or replace any part of the assembly should it fail to operate during the first ten years from 

      the date of original purchase.  

B

.

One year coverage for all other components including grills, housings, controls and 

     accessories furnished by QC Manufacturing Inc. At our option we will repair or replace 

     any part which fails as a result of defective material or workmanship during the first year 

     from the original date of purchase. 

C

. This warranty does not cover any of the following: 

1. Incidental or consequential damage resulting from the operation of our equipment or

any malfunction thereof.

2. Cost of service calls to diagnose the cause of problems or the labor charge to

un-install any components.

3. Product failure or damage due to faulty installation, abuse, misuse, unauthorized

alteration to factory specs, lack of maintenance, or transportation damage.

4. Shipping or postage for warranty claims.

D

.

To obtain service under this warranty, contact the dealer where you purchased the 

     equipment.  If you are unable to find or reach your dealer, contact Customer Service 

     at QC Manufacturing, Inc., at the address below. 

E

.

Please register your product(s) for warranty on line at www.QuietCoolSystems.com 

This warranty is the only warranty extended by QC Manufacturing, Inc. to purchasers or suppliers of our equipment.  QC Manufacturing Inc. disclaims all other 

warranties, express or implied, that arise by operation of the law.

PRODUCT INFORMATION 

QC Serial # 

QC Serial #

QC Serial # 

QC Serial # 

Product Registration: Please register your product on line at www.QuietCoolSystems.com/support/registration Be sure to keep a copy of this warranty form for 

future 

reference and submit proof of purchase with any warranty claim.  QC Manufacturing, Inc. will not process any warranty claim without proof of purchase from 

an authorized QuietCool dealer. Where consumer may have additional warranty rights in accordance with federal and state law, such rights shall supersede those 

stated herein." 

   

 

 

Rev.  1.1.15

Summary of Contents for ES-1500

Page 1: ...1 QUIETCOOLSYSTEMS COM SEE HEAR FEEL THE QUIETCOOL DIFFERENCE THE NATURAL CHOICE FOR ENERGY SAVINGS OWNER S GUIDE ENERGY SAVER CLASSIC LINE...

Page 2: ...n 6 Heat The QuietCool system should be situated away from heat sources 7 Damage Requiring Service Only qualified service personnel should service the QuietCool system The user should not attempt to s...

Page 3: ...r running In contrast our QuietCool whole house fans average at just around 45 dB that s equivalent to quiet conversation The QuietCool system uses a cutting edge patented design to get our sound leve...

Page 4: ...RTANT 1 SQUARE FOOT OF NET FREE VENTING PER 750 CFM REQUIRED VENTILATION 1 SQ FT FOR EACH 750 CFM Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent 14 x 8 0 70 Eave...

Page 5: ...mark the exact location for each fan Take the cardboard cut out template and a small screwdriver with you Make sure the template fits between the framing The rough opening size varies depending on wh...

Page 6: ...place mark its outline with a pencil NOTE Repeat these steps at each location 4 Using a drywall saw or similar device cut out the hole in the ceiling NOTE Repeat these steps at each location 5 Open a...

Page 7: ...the drywall or the joist in the attic While holding it in place install a 1 3 8 drywall screw through the drywall into the flange of the damper box on each side to temporarily hold the box in place Re...

Page 8: ...e quantities of air from the home and particularly if not enough windows are open This could easily back draft gas appliances located inside your home 3 WIRING NOTE Wiring Diagrams are for examples on...

Page 9: ...opening up the handy box Take off the wire nuts within the handy box Unscrew the green ground wire Detach the green ground wire from the power cord Remove the power cord Re attach the ground screw and...

Page 10: ...wire to the top gold screw on the right of the switch Then attach the black wire to the bottom gold screw see Figure 3 2A 3 With a piece of bare copper wire attach it to the green ground screw on the...

Page 11: ...Speed Whole House Fans Tie All Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR HOLD Black High Speed High OFF Low 14 2 Wire Figure 3 2A Power Timer Tie All Ground Bare Copper...

Page 12: ...x from your power source tie the black wire to the black wire on the timer with a wire nut 5 Take a piece of bare copper wire and attach it to the green ground screw on the switch Using a wire nut tie...

Page 13: ...Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR HOLD 14 2 Wire 14 2 Wire Power Source Black Tied Together with Black Red Switch Leg Off On On Off Two Speed Wiring Tie Common Wi...

Page 14: ...windows will lessen the cooling breeze you feel The breeze will flow through your home and make its way to each QuietCool you have in operation As it gets later in the evening and even cooler outside...

Page 15: ...or the labor charge to un install any components 3 Product failure or damage due to faulty installation abuse misuse unauthorized alteration to factory specs lack of maintenance or transportation dam...

Page 16: ...14 1 888 QUIETCOOL 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM QuietCool is Proudly Designed and Built in California...

Reviews: