Operation Manual - Security
Quidway S3000 Series Ethernet Switches
Chapter 1 802.1x Configuration
1-9
server-timeout-value
: Specify how long the duration of a timeout timer of an
Authentication Server is. The value ranges from 100 to 300 in units of second.
supp-timeout
: Specify the authentication timeout timer of a Supplicant. If a Supplicant
has not responded before the specified period expires, Authenticator will resend the
authentication request.
supp-timeout-value
: Specify how long the duration of an authentication timeout timer of
a Supplicant is. The value ranges from 10 to 120 in units of second.
tx-period
: Specify the transmission timeout timer. If a Supplicant has not responded
before the specified period expires, Authenticator will resend the authentication
request.
tx-period-value
: Specify how long the duration of the transmission timeout timer is. The
value ranges from 10 to 120 in units of second.
By default, the
quiet-period-value
is 60s, the
tx-period-value
is 30s, the
supp-timeout-value
is 30s, the
server-timeout-value
is 100s .
1.2.11 Enable/Disable quiet-period Timer
You can use the following commands to enable/disable a quiet-period timer of an
Authenticator (which can be a Quidway Series Ethernet Switch). If an 802.1x user has
not passed the authentication, the Authenticator will keep quiet for a while (which is
specified by
dot1x timer quiet-period
command) before launching the authentication
again. During the quiet period, the Authenticator does not do anything related to 802.1x
authentication.
Perform the following configuration in system view.
Table 1-11
Enable/Disable a quiet-period timer
Operation Command
Enable a quiet-period timer.
dot1x quiet-period
Disable a quiet-period timer
undo dot1x quiet-period
1.3 Display and Debug 802.1x
After the above configuration, execute
display
command in any view to display the
running of the VLAN configuration, and to verify the effect of the configuration. Execute
reset
command in user view to reset 802.1x statistics information. Execute
debugging
command in user view to debug the 802.1x module.