Cautions
•
Do not install the equipment on a thick-piled carpet or rug.
•
Do not install the equipment in a location that is poorly ventilated or stuffy.
•
Pay attention to ventilation when operating the equipment continuously for a long period in
a small room.
•
Install the equipment away from sources of strong magnetic or electric noise.
•
Install the equipment away from monitors or televisions.
•
Remember to use ventilation when printing large volumes or operating the equipment
continuously for a long period.
Installation Environment
Consider the following environment conditions when you select the installation location.
Use a location that is within the following ranges for temperature and humidity.
•
Be careful that condensation does not form.
•
If you install the equipment in a location where the humidity is in a range of less than 30%,
use a humidifier or anti-static mat.
•
The equipment satisfies the certification standards relevant to emissions for Eco-mark No.
155 printers in regard to dust, ozone, styrene, benzene, TVOC, and dispersion of ultrafine
particles. (Testing has been done based on the testing methods in the Blue Angel RAL
UZ-171: 2012 appendix S-M as regards to black and white and color printing by using toner
in a genuine QuickLabel print cartridge.)
Installation Space
•
Select an installation location that is level and can support the weight of the machine
(weight of equipment is about 95 lbs (43 kg)* for the printer and about 42 lbs (19 kg) for the
unwinder).
* Including the print cartridge and other wear items.
•
Install the machine near a power socket. Also, install the equipment so the power socket is
within easy reach so the power plug can be pulled out in an emergency.
•
Do not place things around the machine.
To install the printer and the unwinder on a stand, the stand must be at least 42 inches (1050
mm) wide and 20 inches (500 mm) deep. If you install the printer and the unwinder on a stand
that is too small, they may fall off if they are hanging over the edge of the stand.
Temperature and Humidity
Specification
Temperature range
10 to 30 º C
Humidity range
20 to 70% RH (relative humidity)
Maximum wet-bulb temperature
25 º C
Summary of Contents for QL-300
Page 1: ......
Page 20: ...Installation QL 300 User Guide 20 2 Remove the top layer of packing materials...
Page 28: ...Installation QL 300 User Guide 28 3 Remove the unwinder...
Page 30: ...Installation QL 300 User Guide 30 5 Peel off the tape from two locations...
Page 41: ...Installation QL 300 User Guide 41 Unwinder Black mark Gap sensor...
Page 113: ...Printing QL 300 User Guide 113 Caution Do not touch the belt surface or damage the belt...
Page 274: ...Troubleshooting QL 300 User Guide 274 25 Lift up the fuser and exit unit locking lever...
Page 277: ...Troubleshooting QL 300 User Guide 277 29 Raise the blue lever and install the cutter unit...
Page 359: ...Cleaning QL 300 User Guide 359 2 Press down the flange locking lever 3 Remove the flange...
Page 382: ...Cleaning QL 300 User Guide 382 23 Push down the fuser unit handle and firmly push it inside...
Page 383: ...Cleaning QL 300 User Guide 383 24 Lift up the fuser and exit unit locking lever...
Page 456: ...Safety QL 300 User Guide 456...