9.8 General charger information:
The external charger has been designed to charge two 12
V Gel type batteries connected in series (= 24 V).
9.9 Charger Specification:
WARNING!
Only use chargers for cyclic batteries, Gel-Type with
24V/8A output nominal max.
For more information about the charger
operation, consult the instructions provided with
the charger.
Note:
If the charger is not connected to the control it does
not output charge voltage.
WARNING!
It is possible that the charger’s metallic box may slightly
raise in temperature due to use.
9.10 Charger safety features:
The chargers have features which prevent hazards or
accidents occurring as a result of connecting batteries the
wrong way round, overheating caused by fault conditions
or attempting to charge wrong voltage batteries.
The majority of charger sizes are electrically double
insulated and no earth connection is required. Some
larger sizes may be electrically earthed and this will be
clearly stated on the label.
The 3 pin UK mains input plug contains a replaceable fuse.
The rating of this fuse is shown on the charger label.
WARNING!
Always replace with the same type and size of fuse as
specified. Fitting of different fuses can result in damage to
the charger or failure of the charger to operate properly.
If your charger has been specified for use in Continental
Europe it will contain a European two pin plug which does
not have a fuse. In this case the fuse is located in the
fascia panel of the charger.
9.11 Procedure for connecting the charger and
charging:
The wheelchair can be charged via the charger socket
•
at the front of the VR2 remote control, (Fig. 9.10).
Connect the charger to the mains supply by means of
•
the mains plug and switch on.
Do not leave the charger connected to the battery
•
with the mains disconnected or switch ed off. This
could result in damage to your battery being caused
by deep discharge over a period of time.
Always switch off at the mains before disconnecting
•
the batteries.
9.12 Charger safety and caution notes:
WARNING!
The charger is designed for indoor use. Do not use
•
outdoors or expose to rain, snow, spray or moisture.
When buying replacement batteries or charger always
•
consult your Sunrise Medical service agent.
The charger may be used with other brands of Gel
•
type batteries, subject to written confirmation from the
Technical Department of Sunrise Medical.
If your wheelchair is fitted with the R-Net
control system, the charging process is similar
to that stated above. For full details please see
the separate R-Net Owners Manual.