6.3 Temperature unit Setting 

1. . Press 1 or +, select “uint”, press ENTER, enter into temperature unit setting 

interface, press ENTER again, enter into temperature changer select interface, press 

1 select temperature unit. As following 5-3 

 

>>>

  Enetr   Back

SET

C H 1 - 3   T e m p

u i n t

s l e e p

C l o s e

A l a r m   t e m p   +

A l a r m   t e m p   -

                   

>>>

  Enetr   Back

SET

C H 1 - 3   T e m p

u i n t

s l e e p

    u i n t

C l o s e

A l a r m   t e m p   +

A l a r m   t e m p   -

 

 

℃ ℉

  / 

  STORE    Back

SET

C H 1 - 3   T e m p

u i n t

s l e e p

    u n i t

C l o s e

A l a r m   t e m p   +

A l a r m   t e m p   -

 

                                        pic5-3   

2.  After  selecting  temperature  unit,  press  “STORE”  save,  press  “Back”  return 

setting interface, press “Back” again , return main menu interface.   

 

 

 

 

 

 

 

 

 

6.8 Reset password

   

1. press 1 or +, select “password”, press ENTER, enter reset password interface, 

press ENTER again enter into password interface, press “+” or “

” import 0,   

press 1 import original password 000000, press ENTER affirm, enter into new 

password import interface, If the two passwords are the same ,it will modify the 

password successfully. 

 

>>>

  Enetr   Back

SET

P a s s w o r d

E S D   t e s t

K e y   T o n e

a d r e s s

                   

**

>>>

  Enetr   Back

SET

******

P a s s w o r d

P a s s w o r d

E S D   t e s t

K e y   T o n e

a d r e s s

 

**

>>>

  Enetr   Back

SET

******

P a s s w o r d

E n t e r   o l d   P W D

E S D   t e s t
K e y   T o n e
a d r e s s

                     

**

>>>

  Enetr   Back

SET

******

P a s s w o r d

E n t e r   n e w   P W D

E S D   t e s t

K e y   T o n e

a d r e s s

   

 

 

 

Note

:

 after change password, the temperature cannot be modify, enter 

into parameter setting interface with new right password. 

 

 

 

 

Press ENTER 

Press ENTER 

Page8 

Press ENTER 

Press ENTER 

Page13 

Summary of Contents for TS2200

Page 1: ...Operation Manual Thank you for purchasing an Lead Free Soldering Station It is designed for lead free soldering Please read this manual before operating the unit Store this manual in a safe easily acc...

Page 2: ...ngerous While replace parts or install tips turn the power off and allow the unit to cool to room temperature To prevent damage to the unit and ensure a safe working environment be sure to comply with...

Page 3: ...convenience 5 Anti static device ESD measuring ability Tip Care and Maintenance Select a Correct Tip 1 Select a tip that maximizes contact area between the tip and solder joint Maximizing contact area...

Page 4: ...ns Type TS2200 Temperature displaying type LCD Power consumption 90W Working voltage 220VAC Temperature Range 100 480 212F 896F Temperature Stability 2 Ambient Temperature Max 40 Tip to Ground Resista...

Page 5: ...WER key use for soft switching in hard switching state long press POWER about 3S turn on and working and then press POWER pic4 1 6 12 Language setting 1 Press 1 or select Language press ENTER enter in...

Page 6: ...on iron stand and take up hand shank again start sleep function 5 4 Setting the Temperature CAUTION Make sure the temperature of the unit can be adjusted password is correct or the password is initial...

Page 7: ...l 3 as following 4 2 Temperature setting method the same as CH1 Setting Working Parameters 6 1 Enter into password interface 1 Press 2 and 3 key at the same time enter into setting main menu as follow...

Page 8: ...perature setting interface press ENTER key again CH1 temperature color turn to blue it can be modify press key and key modify value press 1 key move down CH2 temperature color turn to blue it can be m...

Page 9: ...ace 6 8 Reset password 1 press 1 or select password press ENTER enter reset password interface press ENTER again enter into password interface press or import 0 press 1 import original password 000000...

Page 10: ...g interface press Back again return menu interface 6 4 Sleep time setting 1 Press 1 or press ENTER enter into sleep time setting interface press ENTER again enter into sleep time interface press 1 sel...

Page 11: ...Alarm temp press ENTER enter into alarm temperature setting interface press ENTER again select temperature alarm function press 1 select ON or OFF OFF express not alarm ON express alarm press or modi...

Reviews: