16
GB
SBC ADVANCED PLUS MEDIUM - REV005A
BATTERIES
To access the output terminals it is necessary to remove the cover by loosening the two screws which hold it
on (see fig. 1 part A). Before making the connections to the cables from the battery, loosen or remove the cable
clamps by loosening the screws which fix it to the base (fig.1 part B).
WARNING:
during charge, batteries can generate explosive gases, therefore avoid sparks or naked
fl ames. Provide adequate ventilation to the battery area whilst charging.
WARNING:
before connecting the batteries check the polarity of the cables from the battery. Reversing
the polarity, could seriously damage the battery charger even if protected by fuses.
The positive terminal of the battery or of the group of batteries must be connected to one of the positive
terminals of the battery charger. The negative terminal of the battery or of the group of batteries must be con-
nected to the negative terminal of the battery charger (fig. 2). To make the connections use the cable terminals
supplied with the equipment.
EQUIPMENT SUPPLY
The equipment already includes a power cable for AC supply. For connections to an AC supply see fi g.2.
Before powering up the battery charger check that the power supply voltage, described on the rating label,
corresponds to that supplied by the AC supply source.
A 2 pole switch must be installed in the electrical circuit for the sole use of switching the equipment ON & OFF.
The insulation between the contact points of the connections of the AC supply must be at least 3 mm.
The connections to the AC supply must be carried out according to local electrical codes.
WARNING:
before connecting or disconnecting the cables from the electrical terminals of the battery
charger, make sure that the equipment is disconnected from the AC mains and the batteries.
WARNING:
in cases where the power supply cable could be damaged, have this changed by a “Quick
®
”
service centre. In order to avoid accidents, the equipment must only be opened by authorised personnel.
FIG.2
5 cm
5 cm
5 cm
5 cm
BATTERY
N° 3
BATTERY
N° 2
BATTERY
N° 1
BATTERY
SWITCHES
BLUE
YELLOW
GREEN
BROWN
NEUTRAL
EARTH
LIVE
SLAVE B
SLAVE A
MASTER
INSTALLATION - OPERATING