OPERATION MANUAL
TC: ***
℃
Tb: ***
℃
T sense error !
If the bottom sensor is broken, it displays:
TC: ***
℃
Tb: ***
℃
B sense error !
When happening above status, user must stop operating.
If TC is more than 275 during wor
℃
king, the system will also exit the process and back to the initial state.
7. Technics Instruction
Note: Top and bottom Heater will be very hot during working, so please don’ touch the hot housing parts.
Note: The laser alignment device includes a secondary laser device, so don’t see the laser bean directly.
7.1 Soldering Technics (Switch on the System’s Power)
1.
Turn on power switch of each part.
2.
Move PCB Fixture with fixed PCB to make PCB over the Bottom Heater and make the soldered
component between Top Heater and Bottom Heater. The position is easy to be measured with laser
alignment device. The right position should make the red laser point in the center of component. The
component which to solder on the PCB have been aligned before soldering.
3.
Adjust aperture system to get a proper window size.
4.
Select parameter with keyboard. (Refer to “Parameter setting”)
A.
Input password ”000”
B.
Select the required flow, if need to modify, perform relevant operation.
C.
Select “solder” working mode.
D.
Select “IR” laser alignment mode.
E.
Not to change communication speed, and press
“OK” key to exit. the window shows:
ready for flow
TC: ***
℃
Tb: ***
℃
Page 12