INSTALLATION AND USE MANUAL - QUICK B3 SERIES
WATER
Heater
- REV001A
6 - Maintenance
6.0 - B3Series maintenance
WARNING:
if the overtemperature safety device is triggered repeatedly during the use of the water
heater, contact a Quick
®
service centre.
WARNING:
if the power cable is damaged, have it replaced at a Quick
®
service centre. To avoid
accidents, the equipment must only be opened by authorised personnel. The warranty will be void if
the equipment is opened by unauthorised personnel.
•
During the cold season, if the water heater is not in use, it is advisable to empty it using the valve lever (fig. 1 page 7).
This is to avoid damage caused by frost.
•
Periodically check the hydraulic system fittings for leaks; check the tightness of the fastening screws and replace
them if they are worn out or corroded.
•
Periodically check the efficiency of the electrical system.
6.1 - B3Series AC maintenance
WARNING
: Quick
®
water heaters (only
AC
model) are equipped with a double thermostat with manual
reset that cuts off the power supply in the event of too high water temperature.
If this condition occurs, proceed as follows:
It is advisable to check the magnesium anode every 12 months.
Replace it if deteriorated.
This simple preventive maintenance guarantees a long
equipment life over time.
PROCEDURE for SINGLE-PHASE manual reset (only for AC model):
• Interrupt the power supply
• Remove the protection cover (B) to reach the thermostat (C).
•
Use a screwdriver to turn the thermostat knob (fig. 4 page 10) and
set the maximum temperature value.
•
Press the reset button on the double thermostat (fig. 4 page 10).
• Use a screwdriver to turn the thermostat (C) knob and set the
desired temperature value.
•
Refit the protection cover (B).
• Restore the power supply.