Er-2 

 

电机堵转保护

 

 

Motor Rotation 

 

Obstruction Warming 

 

出现此种状况表明电机发生堵转故障,请检查机头是否卡死或缝料

是否太厚,机器是否缺少润滑油负载变重的原因。再检查电机霍尔

是否损坏,检查一切正常还无法排除故障请与经销商联系,非专业

人士禁止打开控制器外壳,以免触电。

 

 

If machine have this problem, it it mean the motor rotation 
obstruction please check the head is stuck or not, sewing materials 
is too heavy or not , the machine lack oil or not. Then check the 
Hall electric machine is good or not. If every thing is good,please 
contact with dealer. Non professionals to ban open controller 
housing to avoid the electric shock. 

 

Er-3 

 

交流输入掉电保护

 

 

The AC input Power 
down Protection 

 

出现此种状况表明断电或者保险丝熔断,请检查电源插头是否插

牢,再检查保险丝是否完好,非专业人士禁止打开控制器外壳,以

免触电。

 

 

If machine have this problem, it is mean the power is failure or 
blowout. Please check the power plug is inserted or not.Then 
check the fuse is good or not. Non professionals to ban open 
controller housing to avoid the electric shock. 

 

Er-4 

 

霍尔信号异常

 

 

Hall Signal Abnormal 

 

出现此种状况表明电机霍尔信号错误,请检查电机四芯插头连接是

否可靠,霍尔信号线是否有断线,插针是否变形。非专业人士禁止

打开控制器外壳,以免触电。

 

 

If machine have this problem, it is mean the Hall signal is 
wrong.Please check motor plug is inserted or not, Hall signal line is 
disconnected or not, the pin is deformation or not. Non 
professionals to ban open controller housing to avoid the electric 
shock. 

 

Er-5 

 

定位器信号检测,上停

 

针故障

 

 

Locator Signal 

 

Detection,Fault on The 

 

Stop Needle up 

 

出现此种状况表明电机传感器信号错误,请检查电机四芯插头连接

是否可靠,传感器信号线是否有断线,插针是否变形。非专业人士

禁止打开控制器外壳,以免触电。

 

 

If machine have this problem, it is mean motor sensor signal is 
wrong.Please check the motor plug is inserted or not,Hall signal 
line is disconnected or not, the pin is deformation or not. Non 
professionals to ban open controller housing to avoid the electric 
shock. 

 

Er-6 

 

定位器信号检测,下停

 

针故障

 

 

Locator Signal 

 

Detection,Fault on The 

 

Stop Needle down 

 

出现此种状况表明电机传感器信号错误,请检查电机四芯插头连接

是否可靠,传感器信号线是否有断线,插针是否变形。非专业人士

禁止打开控制器外壳,以免触电。

 

 

If machine have this problem, it is mean motor sensor signal is 
wrong. Please check the motor plug is inserted or not,Hall signal 
line is disconnected or not, the pin is deformation or not. Non 
professionals to ban open controller housing to avoid the electric 
shock. 

 

Summary of Contents for 8802

Page 1: ...or dew and mist of places 4 Install the control box and other components turn off the power and unplug the power cord 5 To prevent interference or leakage accidents please do the ground work the power...

Page 2: ...nto the back side of machine and tighten up 4 screws with 3mm hexagonal socket 3 Install the controller box Put motor power cable and motor hall cable into controller plug then install the control box...

Page 3: ...s correct 7 Subsequent Installation Install Plug Cover onto the plugs and Tighten the Screw Power cable of control box should be connected with the power supply system power supply system of users mus...

Page 4: ...rpm Heavy duty 3000rpm Light materials3700rpm Heavy duty 3000rpm Maximum Speed Light materials 5000rpm Heavy duty 3500 rpm Light materials 5000rpm Heavy duty 3500 rpm Maximum Torque 2 5N m 2 5N m Over...

Page 5: ...T on is with thread trimming function display T of is without thread trimming function Trimming only for LG03 LG04 4 LED Light Normally it shows strong light pressing one time is microlight one more t...

Page 6: ...emeter value to 1 5 Press S to save the new value display ok and back to P 04 6 Press P to return to the general using mode 5 Trouble Display Error Code Error Meaning Solution Er 1 Over Current Protec...

Page 7: ...achine have this problem it is mean the Hall signal is wrong Please check motor plug is inserted or not Hall signal line is disconnected or not the pin is deformation or not Non professionals to ban o...

Page 8: ...s deformation or not the governor Hall is short or not replace the foot immediately Non professionals to ban open controller housing to avoid the electric shock Er 8 Warming E8 when turnover the machi...