USER MANUAL
16
Heater Abnormity
Temperature sensor is not connected or it is inserted in an error
position, re-connect it after power OFF.
No handle
1. Soldering iron is not connected.
2. Soldering iron is not suitable for the station.
Handle error
Circuit of soldering tip abnormal, check if the connection is right
or not, then re-power on.
Replace a new one.
Sensor Abnormity Heater is damaged, replace a new one.
Soldering Abnormity
Check tip position
1. The soldering tip is not installed or damaged.
2. Check tip position.
2.8.
Tip care and maintenance
Select a Correct Tip
1.
Select a tip that maximizes contact area between the tip and solder
joint. Maximizing contact area gives the most efficient heat transfer,
allowing operators to produce high quality solder joints quickly.
2.
Select a tip that allows good access to the solder joint. Shorter tip
lengths allow more precise control. Longer or angled may be needed
for soldering densely populated boards.
2.9.
Error Messages